HP Insight Management WBEM PCI Device Provider Overview 195
Property Name
Property Implementation
GroupComponent
References
SMX_ComputerSystemChassis
PartComponent
References
SMX_PCISlot
11-4-7 SMX_SystemPCIDevice
Property Name
Property Implementation
GroupComponent
References
SMX_ComputerSystem
PartComponent
References
SMX_PCIDevice
11-4-8 SMX_PCISlotLocation
Property Name
Property Implementation
CIM_ManagedElement
Caption
Same as
ElementLocationTag.
Description
Same as
ElementLocationTag.
ElementName
Same as
ElementLocationTag.
CIM_Location
Name
Unique identifier of the form:
HPQ:SMX_PCISlotLocation:
<
unique_keys
>
PhysicalPosition
Opaque key.
Example for slot 6 in cabinet 1, bay 2 chassis 3 :“01-02-03-FF-FF-
06-FF-85
For Slot 2 in a non-cellular in this system: “FF-FF-FF-FF-FF-02-FF-
85
HP_Location
ElementLocationTagDesc
0 (Hood Tag)
ElementLocationTag
"PCI Slot Location" <physical location>.
Refer to
“Physical Location” for more information.
LocationInfoDesc
Array of numerical enumerators describing values at comparable index in
the LocationInformation array index 1,2, 3, or 4.
LocationInfoDesc[0] per LocationInformation[0] 3 (PCI Slot).