HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Manager WBEM Base Server Provider Overview 19
Property Name
Property Implementation
VirtualUUID[]
If Synergy is enabled, this will contain the logical UUID for the system.
VirtualSerialNumber[]
If Synergy is enabled, this will contain the logical Serial Number for the system.
SMX_ComputerSystemChassis
1-2-3 SMX_ComputerSystemPackage Class
The SMX_ComputerSystemPackage class implements the HP_ComputerSystemPackage class and
associates instances of SMX_ComputerSystem and
SMX_ComputerSystemChassis. There is only one
instance of
SMX_ComputerSystemPackage instantiated on a server.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_Dependency
CIM_SystemPackaging
CIM_ComputerSystemPackage
PlatformGUID
Computer system physical UUID value from SMBIOS.
HP_ComputerSystemPackage
Antecedent
References
SMX_ComputerSystemChassis
Dependent
References
SMX_ComputerSystem
SMX_ComputerSystemPackage
1-2-4 SMX_OperatingSystem Class
The SMX_OperatingSystem class implements the CIM_OperatingSystem class to model the system
operating system. There is only one instance of
SMX_OperatingSystem instantiated on a server.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
On Linux, first line of /etc/issue.
On ESXi, output of
vmware -v
Description
Output of
uname -v
.