HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Manager WBEM Ethernet 127
Property Name Property Implementation
RecommendedActions
Check the Ethernet Team and Ethernet Team Member status. View
the System Event Log for additional information.
HP_AlertIndication
Summary
Ethernet team reported change in number of active members.
EventCategory
9
(Network Device)
EventSubCategory
12
(Ethernet team)
ProbableCause
1
(Other)
ProbableCauseDescription
Ethernet team reported change in number of active members
5-4 Physical Location
The Ethernet Port Physical Location is a string representing the physical location of the Ethernet Port. This
string should represent the physical location of the device with which an end-user can uniquely locate the
device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags.
The following table lists the properties implemented. Any combination of the following applicable
descriptors could be used to better define the device location.
All Systems
HP Integrity
Cellular Servers
HP BladeServers in C3000/
C7000 Enclosures
Slot=<
num>
Cabinet=<
num
>
Blade=<
num
>
Embedded
Controller=<
logical_controller_id>
Bay=<num>
RootPort=<num> (if embedded on
System Board)
System Mainboard (referring to System
Board/motherboard)
Chassis=<num>
Mezzanine=<num> (I/O Mezzanine
slot num)