HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Manager WBEM Ethernet 116
Property Name Property Implementation
MonitorLANEndpoints
If enabled, events related to SMX_EthernetLANEndpoint are
generated. Default, disabled.
MonitorPorts
If enabled, events related to SMX_EthernetPort are generated.
Default, enabled.
MonitorRedundancySets
If enabled, events related to SMX_EthernetTeam are generated.
Default, true.
PolInterval
The longest interval between network status polls, in
seconds.
Value 0 disables polling and is not recommended. Using very low
values can increase CPU utilization. Default 200.
5-3 Supported Indications
The following table describes the properties that are common to all of the SMX Ethernet Port Provider
indications that are implemented for server platforms, where available.
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
IndicationTime
Time of indication
CIM_AlertIndication
EventTime
Time of the event or time of the indication if event time unknown
SystemName
SMX_ComputerSystem.Name
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
HP_AlertIndication
ProviderVersion
Provider Version in the format
VV.UU.FF
For example:
01.05.00
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType
On ESX, 39 (VM)
On Linux, 36 (Linux)