HP Insight Management WBEM Providers 2.
Legal notices © Copyright 2008, 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP will not be liable for technical or editorial errors or omissions contained herein. Confidential computer software.
Contents 1 HP Insight Manager WBEM Base Server Provider Overview ........................................................... 12 Setting Up the Provider .......................................................................................................... 12 Using the Provider ................................................................................................................ 12 1-2-1 SMX_ComputerSystem Class ...................................................................................
3-2-8 3-2-9 3-2-10 3-2-11 3-2-12 3-2-13 3-2-14 3-2-15 3-2-16 3-2-17 3-2-18 3-3 3-4 3-4-1 3-4-2 3-4-3 3-4-4 4 SMX_ProcessorCoreComponent Class..................................................................................... 56 SMX_HWThreadComponent Class ......................................................................................... 57 SMX_AssociatedProcessorCacheMemory Class ............................................................. 57 SMX_ProcessorCollection Class .......................
-2-26 5-2-27 5-2-28 5-2-29 5-2-30 5-2-31 5-3 5-3-1 5-3-2 5-3-3 5-3-4 5-3-5 5-3-6 5-3-7 5-3-8 5-3-9 5-3-10 5-3-11 5-3-12 5-3-13 5-4 6 6-1 6-2 SMX_EthernetGroupHostedCollection ......................................................................... 111 SMX_EthernetTeam ................................................................................................... 111 SMX_EthernetTeamMember .......................................................................................
-2-30 6-2-31 6-2-32 6-2-33 6-2-34 6-3 6-4 7 7-1 7-2 8 8-1 8-2 9 SMX_FCHBAComputerSystemSCSIProtocolController .................................................... 150 SMX_FCHBAFCPortSCSIProtocolEndpoint.................................................................... 150 SMX_FCHBASCSIProtocolControllerFCPort .................................................................. 151 SMX_FCHBASystemServiceAccessPoint .......................................................................
11-4-2 11-4-3 11-4-4 11-4-5 11-4-6 11-4-7 11-4-8 11-4-9 11-5 11-6 12 SMX_PCICard .......................................................................................................... 192 SMX_PCISlot ............................................................................................................ 193 SMX_PCICardInSlot .................................................................................................. 194 SMX_RealizesPCIDevice ..................................................
13-2-4 13-3 14 SMX_PRPBaseServerECTP Class ................................................................................. 231 Provider Indications ............................................................................................................ 231 HP Insight Management WBEM System Temperature Sensor Provider ........................................ 232 Setting Up the Provider ........................................................................................................
15-2-38 15-2-39 15-2-40 15-2-41 15-2-42 15-2-43 15-2-44 15-2-45 15-2-46 15-2-47 15-2-48 15-2-49 15-2-50 15-2-51 15-2-52 15-2-53 15-2-54 15-2-55 15-2-56 15-2-57 15-2-58 15-2-59 15-2-60 15-2-61 15-2-62 15-2-63 15-2-64 15-2-65 15-2-66 15-2-67 15-2-68 15-2-69 15-2-70 15-2-71 15-2-72 15-2-73 15-2-74 15-2-75 15-2-76 15-2-77 15-2-78 15-2-79 15-2-80 15-2-81 15-2-82 15-2-83 15-2-84 15-2-85 15-2-86 15-2-87 15-2-88 15-2-89 15-2-90 15-2-91 SMX_SAArraySystemSCSIProtocolController (Association)..........................
15-2-92 15-2-93 15-2-94 15-2-95 15-2-96 15-2-97 15-3 15-3-1 15-3-2 15-3-3 15-3-4 15-3-5 15-3-6 15-3-7 15-3-8 15-3-9 15-3-10 15-3-11 15-3-12 15-3-13 15-3-14 15-3-15 15-3-16 15-3-17 15-3-18 15-3-19 15-3-20 15-3-21 15-3-22 15-3-23 15-3-24 15-3-25 15-3-26 15-3-27 15-4 16 SMX_PortControllerISASPort (Association) ................................................................... 302 SMX_ArraySystemTSASSCSIProtocolEndpoint (Association) ...........................................
16-2-16 16-2-17 16-2-18 16-2-19 16-3 16-3-1 16-3-2 16-3-3 16-3-4 16-3-5 16-3-6 16-3-7 16-3-8 16-3-9 16-3-10 17 SMX_FanInSlot Class................................................................................................. 382 SMX_FanSpeedSensor .............................................................................................. 382 SMX_SystemFanSensor.............................................................................................. 384 SMX_AssociatedFanSensor ..................
1 HP Insight Manager WBEM Base Server Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
This provider returns instances in the root/hpq namespace.
Property Name Property Implementation CIM_ManagedSystemElement Status Same as OperationalStatus[0]. OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of any connected subsystem. OperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) OperationalStatus 2 (OK) 3 (Degraded) 6 (Error) 10 (Stopped) The status values of the subsystems that make up the overall operational status are contained in OperationalStatus[1-n].
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName SMX_ComputerSystem Roles Computer system roles string: initialized to not set. CIM_ComputerSystem OtherIdentifyingInfo[0]: Where: is the computer system physical GUID string.
Property Name Property Implementation IdentifyingDescriptions[0]: CIM:GUID IdentifyingDescriptions[1]: CIM:MAC IdentifyingDescriptions[2]: CIM:Model:SerialNumber IdentifyingDescriptions[3]: IdentifyingDescriptions CIM:Tag IdentifyingDescriptions[4] CIM:CorrelatableID IdentifyingDescriptions[5] HPQ:ProductID IdentifyingDescriptions[6] HPQ:SMXTarget Dedicated 0 (Not Dedicated) HP_ComputerSystem Name Computer system DNS name returned by uname.
Property Name Property Implementation IdentifyingNumber The computer system physical GUID string. Model The computer system model string.
Property Name Property Implementation ElementName Computer system product name (model) string. Manufacturer Computer manufacturer string. Model Computer system product name (model) string. SerialNumber Computer system physical serial number. UserTracking Computer system asset tag string (writable property; persistent across reboots). Name Computer system product name (model) string. Status OK StatusDescriptions Description of the state of the chassis, for example System is functional.
Property Name Property Implementation VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. SMX_ComputerSystemChassis 1-2-3 SMX_ComputerSystemPackage Class The SMX_ComputerSystemPackage class implements the HP_ComputerSystemPackage class and associates instances of SMX_ComputerSystem and SMX_ComputerSystemChassis.
Property Name ElementName Property Implementation Output of uname -s.
Property Name LastBootUpDateTime Property Implementation Time when the operating system was last booted SMX_OperatingSystem 1-2-5 SMX_RunningOS Class The SMX_RunningOS class implements the CIM_RunningOS class and associates the SMX_ComputerSystem instance and a SMX_OperatingSystem instance. The following table lists the properties implemented.
Property Name Property Implementation References CIM_RegisteredProfile ConformantStandard References CIM_ManagedElement ManagedElement (HP_ComputerSystem for server and network profiles, the storage computer system for storage profiles) HP_ElementConformsToProfile SMX_BaseServerECTP 1-2-8 SMX_SMXSoftwareIdentity Class The SMX_SMXSoftwareIdentity implements the HP_SoftwareIdentity class to model the SMX software identification information. The following table lists the properties implemented.
Property Name Property Implementation CIM_SoftwareIdentity Opaque string using HPQ as OrgID InstanceID For example: HPQ:SMX_SMXSoftwareIdentity-1. MajorVersion The first numeric value in the VersionString. MinorVersion The second numeric value in the VersionString. RevisionNumber The third numeric value in the VersionString. VersionString Version of SMX, for example: 02.00.00.
Property Name Property Implementation CIM_InstalledSoftwareIdentity InstalledSoftware References CIM_SoftwareIdentity System References CIM_ComputerSystem SMX_SMXInstalledSoftwareIdentity 1-2-10 SMX_SystemFirmware Class The SMX_SystemFirmware class implements the HP_SoftwareIdentity class and describes the firmware found on the server system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the firmware.
Property Name Property Implementation Opaque string using HPQ as OrgID InstanceID For example: HPQ:SMX_SystemFirmware: Where: is used to identify the instance. For example: HPQ:SMX_SystemFirmware:1 MajorVersion The firmware major version. MinorVersion The firmware minor version. VersionString The firmware version.
Property Name Property Implementation InstalledSoftware References SMX_SystemFirmware System References HP_ComputerSystem 1-2-12 SMX_SystemElementFirmwareIdentity Class The HP_SystemElementFirmwareIdentity class implements the HP_ElementSoftwareIdentity class and associates the HP_ComputerSystem instance and SMX_SystemFirmware instances. The following table lists the properties implemented.
Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of the indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. For example: 01.05.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 1 ProviderName HP WBEM RecommendedActions No action is recommended. HP_AlertIndication Summary WBEM Providers started ProbableCause 1 (Other) ProbableCauseDescription WBEM Providers Started HP_DeviceIndication: WBEM Providers Informational Test Indication 1-3-2 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_AlertIndication Description This is an information test event.
Property Name PerceivedSeverity Property Implementation 3 (Warning) CIM_AlertIndication Description This is a warning test event. AlertType 5 (Device Alert) EventID 2 ProviderName HP Test RecommendedActions No action is recommended.
Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Warning) CIM_AlertIndication Description The system has rebooted from an Automatic Server Recovery (ASR) event. AlertType 5 (Device Alert) EventID 1 ProviderName HP Recovery RecommendedActions Determine the nature of the ASR event and take corrective action.
Property Name Property Implementation ProbableCause 15 (Temperature Unacceptable) ProbableCauseDescription Thermal reboot occurred 1-3-7 HP_DeviceIndication: POST Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Warning) CIM_AlertIndication Description Power-On Self-Test errors occurred during the last system startup.
2 HP Insight Management WBEM Blade System Lite Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Blade System Lite provider extends the management capability of referencing profiles by adding the capability to represent the Distributed Management Task Force (DMTF) Modular System Profile in HP specific ways. While this profile is based on the DMTF Modular System Profile, it does not conform to that profile.
2-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
Property Name Property Implementation CIM_ManagedElement A description of the class. For example, if enclosure name exists: Caption HP BladeSystem enclosure otherwise: HP BladeSystem enclosure A description of the class. For example, if enclosure name exists: Description HP BladeSystem enclosure otherwise: HP BladeSystem enclosure A description of the class.
Property Name Property Implementation 0 (Unknown), enclosure status: Unknown HealthState 5 (OK), enclosure status: OK 10 (Degraded/Warning), enclosure status: Degraded 20 (Major Failure), enclosure status: Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName SMX_BladeEnclosureCS CIM_ComputerSystem Dedicated 2 (Other) OtherDedicatedDescriptions Modular IdentifyingDescriptions
Property Name Property Implementation ManagementIPAddress The enclosure’s management IP address. ManagementURL The URL of the enclosure’s management web-based user interface. SerialNumber The serial number of the blade enclosure. ProductID The product ID of the blade enclosure. RackName The name of the rack. RackUUID The UUID of the rack. EnclosureName Then name of the blade enclosure.
Property Name Property Implementation Describes the group operational status of the blade enclosure collection. The group operational status represents the ‘worst-of’ algorithm for all individual enclosure statuses in HP_BladeEnclosureCS.OperationalStatus[0].
2-2-4 SMX_MemberOfBladeEnclosureCollection Class The SMX_MemberOfBladeEnclosureCollection class implements the HP_MemberOfBladeEnclosureCollection class and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption A caption for the class. For example Server Blade Enclosure Firmware. Description A description for the class. For example HP Server Blade Enclosure Firmware. ElementName OA CIM_ManagedSystemElement A description of the class.
Property Name Property Implementation IdentifyingInfoValue HPQ:OA IdentifyingInfoType CIM:SoftwareFamily HP_BladeEnclosureFW 2-2-7 SMX_BladeEnclosureElementFWIdentity Class The SMX_BladeEnclosureElementFWIdentity class implements the HP_BladeEnclosureElementFWIdentity class and associates a blade enclosure to its corresponding firmware. The following table lists the properties implemented.
Property Name Property Implementation CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System References HP_BladeEnclosureCS InstalledSoftware References HP_BladeEnclosureFW 2-2-9 SMX_BladeCSLocation Class The SMX_BladeCSLocation class implements the HP_Location class and is used to model the server blade location within an enclosure. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the Blade location.
Property Name Property Implementation PhysicalPosition Where: represents the blade bay slot position printed on the enclosure labeling. HP_Location ElementLocationTag The computer system name. ElementLocationTagDesc 24 (Blade) LocationInformation[0]: LocationInformation The blade bay number within the enclosure.
3 HP Insight Management WBEM CPU Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) CPU provider implements and extends classes described in this document to model the system processors. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP CPU Profile (P00106) HP WBEM TC 1.0.0 HP CPU Consolidated Status Profile (P00107) HP WBEM TC 1.0.
3-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_ProcessorCollection • SMX_HostedProcessorCollection • SMX_MemberOfProcessorCollection • SMX_ProcessorChip • SMX_RealizesProcessor • SMX_SystemPhysicalProcessor • SMX_ProcessorLocation • SMX_ProcessorElementLocation The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation ( Family Model y Stepping ) Where: is the processor brand string, ( is the CPU architecture type, is the processor family number, is the processor model number and z is the processor stepping number. Description For example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName computer system name CreationClassName SMX_Processor DeviceID Proc where n is the processor number.
Property Name AddressWidth Property Implementation 32 – for x86 processors 64 – for x64 processors external bus clock speed in MHz ExternalBusClockSpeed For example: 533 For x86 processors: Characteristics[0] 3 (32-bit Capable) Characteristics For x64 processors: Characteristics[0] 3 (32-bit Capable) Characteristics[1] 2 (64-bit Capable) Number of enabled and operational cores for this processor NumberOfEnabledCores For example: 1, 2, 4 Stepping Stepping for processor Role Processor Role Unique
Property Name Property Implementation Caption Processor Capabilities Description Processor Capabilities CIM_Capabilities HPQ:SMX_ProcessorCapabilities: InstanceID Where: is a unique number.
Property Name Property Implementation ( Family Model Stepping ) (Processor: Core:) Description Where: is the processor brand string, is the CPU architecture type, is processor family number, is processor model number, is processor stepping number, is the processor number, and is the core number. For example: Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation EnabledState 2 (Enabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_ProcessorCore HPQ:SMX_ProcessorCore Proc:
Core: InstanceID CoreEnabledState Where: is the processor number and is the core number.
Property Name Property Implementation Where:
is the processor number, is the core number, and is the thread number ( Family Model Stepping Processor: Core: Thread:) Description Where: is the processor brand string, ( is the cpu architecture type, is the processor family number, is the processor model number and is the processor stepping number, is the processor number, is the core number, and
Property Name Property Implementation 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_HardwareThread HPQ:SMX_HardwareThread:
Property Name Property Implementation Level Data Cache where is the cache level number Level Instruction Cache where is the cache level number Description Level Unified Cache where is the cache level number For example: Level 1 Data Cache Level 2 Unified Cache Level Data Cache where is the cache level number Level Instruction Cache where is the cache level number ElementName Level Unified Cache where is the cache level number For example: Level 1 Data Cac
Property Name Property Implementation RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName Computer system name CreationClassName SMX_CacheMemory Proc
, Level Cache Where: is the processor number, is the cache level number, and is the cache type (Data, Instruction, or Unified) Proc , Core , Level Cache DeviceID Where: is the processor number, is the cache level nu
Property Name Property Implementation CIM_Component CIM_SystemComponent CIM_SystemDevice HP_SystemProcessor SMX_SystemProcessor GroupComponent References SMX_ComputerSystem PartComponent References SMX_Processor 3-2-7 SMX_ProcessorElementCapabilities Class The SMX_ProcessorElementCapabilities class extends the CIM_ElementCapabilities class and associates SMX_Processor and SMX_ProcessorCapabilities instances. The following table lists the properties implemented.
Property Name Property Implementation HP_ProcessorCoreComponent SMX_ProcessorCoreComponent GroupComponent References SMX_Processor PartComponent References SMX_ProcessorCore 3-2-9 SMX_HWThreadComponent Class The SMX_HWThreadComponent class extends the CIM_ConcreteComponent class and associates an SMX_ProcessorCore instance with SMX_HardwareThread instances. The following table lists the properties implemented.
Property Name Property Implementation 0 (Unknown) 1 (Other) Level 2 (Not Applicable) 3 (Primary) 4 (Secondary) 5 (Tertiary) 0 (Unknown) 1 (Other) WritePolicy 2 (Write Back) 3 (Write Through) 4 (Varies with Address) 5 (Determination Per I/O) 0 (Unknown) 1 (Other) CacheType 2 (Instruction) 3 (Data) 4 (Unified) LineSize Cache line size in bytes 0 (Unknown) 1 (Other) ReadPolicy 2 (Read) 3 (Read-Ahead) 4 (Read and Read-Ahead) 5 (Determination Per I/O) HP Insight Management WBEM CPU Provider Overview
Property Name Property Implementation 0 (Unknown) 1 (Other) 2 (Direct Mapped) Associativity 3 (2-way Set-Associative) 4 (4-way Set-Associative) 5 (Fully Associative) 6 (8-way Set-Associative) 7 (16-way Set-Associative) HP_AssociatedCacheMemory SMX_AssociatedProcessorCacheMemory Antecedent References SMX_CacheMemory Dependent References SMX_Processor 3-2-11 SMX_ProcessorCollection Class The SMX_ProcessorCollection class extends the HP_GroupSystemSpecificCollection class.
Property Name Property Implementation GroupOperationalStatus[0] contains the processors consolidated status. GroupOperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) GroupOperationalStatus 5 (Predictive Failure) 6 (Error) 10 (Stopped) The status values of the processors that make up the overall group operational status are contained in GroupOperationalStatus[1-n].
Property Name Property Implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection SMX_HostedProcessorCollection Antecedent References SMX_ComputerSystem Dependent References SMX_ProcessorCollection 3-2-13 SMX_MemberOfProcessorCollection Class The SMX_MemberOfProcessorCollection class extends the CIM_MemberOfCollection class and associates the SMX_ProcessorCollection instance with an SMX_Processor instance. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedSystemElement Processor in Name For text representing the CPU location, refer to “Physical Location”. 0 (Unknown) 2 (OK), when CPU is enabled and operational OperationalStatus 5 (Predictive Failure), when IML error info logged for this CPU 6 (Error), when CPU is disabled via POST error 10 (Stopped), when CPU is disabled via RBSU StatusDescriptions[0] text per OperationalStatus[0]: Unknown.
Property Name Property Implementation ( Family Model Stepping ) Description Where : is the processor brand string, is the CPU architecture type, is the processor family number, is the processor model number and is the processor stepping number. For example: Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation Stepping ProcessorChipRevision Where: is the processor stepping number SMX_ProcessorChip 3-2-15 SMX_RealizesProcessor Class The SMX_RealizesProcessor class extends the CIM_Realizes class and associates SMX_Processor instances with SMX_ProcessorChip instances. The following table lists the properties implemented.
Property Name PartComponent 3-2-17 Property Implementation References SMX_ProcessorChip SMX_ProcessorLocation Class The SMX_ProcessorLocation class implements the HP_Location class which extends the class CIM_Location. For ProLiant systems, processor location is denoted by the use of a slot number designator and a socket number designator.
Property Name Property Implementation CIM_Location HPQ:SMX_ProcessorLocation: Where: is the slot number Name HPQ:SMX_ProcessorLocation: Where: is the socket number HPQ:SMX_ProcessorLocation: Where: is the slot number and is the socket number Where: is the slot number (when no socket number exists) PhysicalPosition Where: is the socket number (when no slot number exists) Where: is the slot number and is the socket number For text representing the
Property Name Property Implementation If only socket number is available: LocationInfoDesc[0]: 4 (Socket) indicates that the first element of the LocationInformation array contains the socket number If only slot number is available: LocationInfoDesc LocationInfoDesc[0]: 0 (Slot), indicates that the second element of the LocationInformation array contains the slot number If both socket and slot numbers are available: LocationInfoDesc[0]: 4(Socket), indicates that the first element of the LocationInformati
The following table lists the properties implemented. Any combination of the following applicable descriptors could be used to better define the device location.
Property Name NetworkAddresses Property Implementation Contains a list of all the IP addresses of the computer system generating the indication. On ESX, 39 (VM). OSType On Linux, 36 (Linux). OSVersion The operating system version of the computer system generating the indication in the following format: .. SystemFirmwareVersion Array of firmware versions of the computer system generating the indication.
3-4-3 HP_DeviceIndication: Processor Disabled by BIOS or EFI Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication Description CPU has been disabled by BIOS or EFI AlertType 5 (Device Alert) EventID 2 EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Enable processor via BIOS or EFI HP_AlertIndication Summary CPU has been disabled by BIOS or EFI ProbableCause 1 (Other) 3-4-4 HP_DeviceIndication: Processor Predicted
Summary CPU Predictive Failure detected ProbableCause 1 (Other) HP Insight Management WBEM CPU Provider Overview 71
4 HP Insight Management WBEM Configuration Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Configuration (Config) Record Log provider implements the Configuration Snapshot Log on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.
This provider supports the following classes: • SMX_ConfigRecordLog • SMX_ConfigLogEntry • SMX_ConfigLogManagesRecord • SMX_ConfigUseOfLog The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the property name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name HealthState Property Implementation 5 (OK), when OperationalStatus[0]=2 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not applicable) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords 1 – Only the most recent snapshot of the configuration will be available. CurrentNumberOfRecords Number of records in the Config log (SMX_ConfigLogEntry instances).
Property Name Property Implementation CIM_ManagedElement Caption Config record log entry. Description Config record log entry. ElementName Config record log entry. CIM_RecordForLog CIM_LogEntry InstanceID Opaque key. LogInstanceID SMX_ConfigRecordLog.InstanceID LogName SMX_ConfigRecordLog.Name RecordID Config record number. CreationTimeStamp Config log event creation time stamp. HP_CommonLogEntry RecordDataType 3 (Delimited) RawData Instances in CIM-XML encoding.
4-2-3 SMX_ConfigLogManagesRecord Class The SMX_ConfigLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of HP_RecordLog and HP_LogEntry. The following table lists the properties implemented. Property Name Property Implementation CIM_LogManagesRecord HP_LogManagesRecord Log Reference HP_CommonRecordLog. Record Reference HP_CommonLogEntry.
5 HP Insight Manager WBEM Ethernet Description The HP Insight Management Web-Based Enterprise Management (WBEM) Ethernet Port provider implements and extends Common Information Model (CIM) classes described in this document to model the ethernet port. These classes reside in the local host OS CIM Object Manager (CIM OM) on each individual monitored system and describe the ethernet ports, associated controllers, and logical ethernet interfaces that are available in the system.
5-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_EthernetMemberOfCollection • SMX_EthernetGroupHostedCollection • SMX_EthernetTeam, • SMX_EthermetTeamMember • SMX_HostedEthernetTeam • SMX_EthernetTeamToLANEndpoint • SMX_EthEventSettings The tables in the following sections describe the properties of the supported classes.
Property Name ElementName Property Implementation Same as Caption. CIM_ManagedSystemElement HealthState 5 (OK), 10 (Degraded), 20 (MajorFailure) The logical MAC address of the Ethernet Port, typically for the format FFFFFFFFFFFF Name Where: each is a text representation of a hexadecimal digit 0x0 - 0xF.
Property Name Property Implementation CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice CreationClassName SMX_EthernetPort DeviceID HPQ:SMX_EthernetPort: SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem Current bandwidth in bits per second if port has link (value is 0, MaxSpeed otherwise).
Property Name LinkTechnology Property Implementation 2 (Ethernet) The logical MAC address of the Ethernet Port, typically for the format FFFFFFFFFFFF Permanent Address Where: each is a text representation of a hexadecimal digit 0x0 - 0xF. Unique number assigned to each Ethernet Port on a given ethernet PortNumber controller in the form of . These numbers are not unique across multiple controllers that exist on the same system. Current bandwidth in bits per second.
Property Name Property Implementation 53 (1000BaseT), 55 (10GBaseT) 54 (2500BaseT) 55 (10GBaseT) 100 (100Base-FX) 101 (1000Base-SX) 102 (1000Base-SX) 103 (1000Base-LX) 104 (1000Base-CX) 105 (10GBase-SR) 106 (10GBase-SW) 107 (10GBbase-LX4) 108 (10GBase-LR) 109 (10GBase-LW) 110 (10GBase-ER) 111 (10GBase-EW) Array of 16 bit unsiged integers advertising the capabilities of the EthernetPort: Capabilities[] 0 (Unknown) 1 (Other) 2 (AlertOnLan) 3 (WakeOnLan) HP Insight Manager WBEM Ethernet 83
Property Name Property Implementation Capability Descriptions[0] per Capabilities[0]. Text descriptions for the Capabilities array above. For example: CapabilityDescriptions[] Unknown Other Alert On LAN Wake On LAN EnabledCapabilities[] NetworkAddresses[] Specifies which of the Ethernet Ports capabilities are enabled. Array of MAC addresses affiliated with port. Formatted like 001122334455 with no delimiting.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement LAN Endpoint information for OS Exposed Ethernet Port information.
Property Name Property Implementation Degraded Error CIM_LogicalDevice CIM_EnabledLogicalElement CIM_ServiceAccessPoint CreationClassName SMX_EthernetLANEndpoint SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem CIM_ProtocolEndpoint Text representing of what the operating system labels this endpoint. Description For example: eth3 LAN Endpoint information for OS Exposed Ethernet Port information.
Property Name Property Implementation CIM_LANEndpoint Text representing the principal unicast address used in communication with the LAN Endpoint. Twelve hexadecimal digits. MACAddress For example: 0102a3b40506 HP_EthernetLANEndpoint 5-2-4 SMX_EthernetLANHostedAccessPoint Class The SMX_EthernetLANHostedAccessPoint class implements the HP_EthernetLANHostedAccessPoint class and associates the Ethernet LAN Endpoint to the Computer System in a managed system.
The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint Antecedent Reference to SMX_EthernetPort. Dependent Reference to SMX_EthernetPortLANEndpoint. 5-2-6 SMX_EthernetPortController Class The SMX_EthernetPortController class implements the HP_EthernetPortController class and is a logical device corresponding to a hardware Ethernet network controller.
Property Name Property Implementation Ethernet Controller CIM_ManagedSystemElement HealthState 5 (OK - normal operation) A description of the class. Name For example: Ethernet Controller controller_id OperationalStatus 2 (OK - normal operation) StatusDescriptions Ethernet Controller status: OK CIM_LogicalDevice CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName SMX_EthernetPortController SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.
Property Name Property Implementation CIM_PortController ControllerType 2 (Ethernet) ControllerVersion Hardware revision number of the controller or None if unknown 5-2-7 SMX_EthernetPortControllerEthernetPort Class The SMX_EthernetPortControllerEthernetPort class implements the HP_EthernetPortControllerEthernetPort class and associates an Ethernet Port Controller to its controlled Ethernet Ports. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Product name.
Property Name Property Implementation For example: Controller (num_ports-port): Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21) ElementName Same as Name property Text representing vendor information from PCI configuration space.
Property Name Property Implementation 9 (Module/Card) HP_EthernetPortPhysicalPackage SMX_EthernetControllerPhysicalPackageEthernetController Class 5-2-9 The SMX_EthernetControllerPhysicalPackageEthernetController class implements the HP_EthernetControllerPhysicalPackageEthernetController class and associates an Ethernet Port Controller Physical Package to its logical Ethernet Port Controller. The following table lists the properties implemented.
Property Name Property Implementation Product Name. ElementName For Example: 2 port controller: Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21) Value of ElementLocationTag prefaced with either Embedded Description Ethernet Controller Caption or Ethernet Controller in Same as Description. CIM_Location Name PCISLOT or EMBEDDED ETHERNET Opaque key.
Property Name Property Implementation Array of numerical enumerators describing values at comparable index in the LocationInformation array index 1, 2, 3, or 4. LocationInfoDesc[0] per LocationInformation[0] 3 (PCI Slot).
SMX_EthernetControllerPhysicalPackageEthernetControlle rLocation Class 5-2-11 The SMX_EthernetControllerPhysicalPackageEthernetControllerLocation class implements the HP_EthernetControllerPhysicalPackageEthernetControllerLocation class and associates SMX_EthernetControllerPhysicalPackageto its logical SMX_EthernetControllerLocation. The following table lists the properties implemented.
Property Name Value Operating System ethernet device name. Description For example: eth1. CIM_ManagedSystemElement HealthState Same as associated LAN Endpoint.
Property Name Value SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.Name CIM_ProtocolEndpoint 0 (Unknown) 2 (OK) OperationalStatus 3 (Degraded) 6 (Error) CIM_IPProtocolEndpoint How the Address was assigned to this IP Protocol Endpoint. 0 (Unknown) AddressOrigin 3 (Static) 4 (DHCP) IPv4Address Only initialized if IP interface advertises a valid IPv4 Address. IPv6Address Only initialized if IP interface advertises a valid IPv6 Address.
Property Name Value 5 (Link Local Unicast) 7 (Embedded IPv4 Address) Unsigned integer. Only initialized if IP interface advertises a valid IPv6SubnetPrefixLength IPv6 Address. It is used to describe the prefix length of the IPv6Address subnet (experimental schema.) PrefixLength Same as IPv6SubnetPrefixLength (non-experimental schema.) Opaque Key. Name SMX scoped instance name.
Property Name SubnetMask Value Text representing the mask of the IPv4 address, if defined; otherwise, 0.0.0.0/ HP_IPProtocolEndpoint 5-2-13 SMX_IPProtocolBindsToEthernetLANEndpoint Class The SMX_IPProtocolBindsToEthernetLANEndpoint class implements the HP_IPBindsToEthernetLANEndpoint class and associates an instance of an IPProtocolEndpoint with its representative Ethernet LAN Endpoint instance. The following table lists the properties implemented.
Property Name Property Implementation CIM_HostedDependency CIM_HostedAccessPoint HP_EthIPHostedAccessPont Antecedent Reference to SMX_ComputerSystem Dependent Reference to SMX_IPProtocolEndpoint 5-2-15 SMX_EthernetRemoteServiceAccessPoint Class The SMX_EthernetRemoteServiceAccessPoint class implements the HP_RemoteServiceAccessPoint class and describes the managed systems view of the default gateway. The following table lists the properties implemented.
Property Name CreationClassName Property Implementation SMX_RemoteServiceAccessPoint A unique description of the gateway. Name For example: RemoteServiceAccessPoint: Gateway for interface_name SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.Name CIM_RemoteServiceAccessPoint 0 (Unknown) AccessContext 2 (Default Gateway) If ProtocolIFType = 4095 (IPv4), then text value will be dotdelimited IP address of default gateway followed by the IPv4 netmask; otherwise, 0.0.0.
5-2-16 SMX_EthernetRemoteAccessAvailableToIPEndpoint Class The class implements the HP_RemoteAccessAvailableToIPEndpoint class and associates the Default Gateway represented by the SMX_EthernetRemoteServiceAccessPoint instance to the IP Protocol Endpoint that has access to it. The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_RemoteAccessAvailableToElement Boolean true if only 1 default and only 1 gateway is present.
Property Name Property Implementation CIM_HostedDependency CIM_HostedAccessPoint HP_EthernetLANHostedAccessPoint Antecedent Reference to SMX_ComputerSystem Dependent Reference to SMX_EthernetRemoteServiceAccessPoint 5-2-18 SMX_EthernetStatistics SMX_EthernetStatistics implements the class HP_EthernetStatistics. The following table lists the property implementation for SMX_EthernetStatistics. Note: Currently implemented only in VMware ESXi platform.
Property Name StatisticTime Property Implementation Time of current statistics CIM_NetworkPortStatistics BytesReceived BytesTransmitted PacketsReceived Total number of bytes received Total number of bytes transmitted Total number of packets received CIM_EthernetPortStatistics AlignmentErrors DeferredTransmissions ExcessiveCollisions See CIM_EthernetPortStatistics mof. See CIM_EthernetPortStatistics mof. See CIM_EthernetPortStatistics mof. FCSErrors See CIM_EthernetPortStatistics mof.
5-2-19 SMX_EthernetPortStatisticalData SMX_EthernetPortToStatisticalData associates Ethernet Ports to Ethernet Port Statistics. Property Name Property Implementation CIM_ElementStatisticalData Key:ManagedElement Key:Stats Reference SMX_EthernetPort Reference SMX_EthernetStatistics HP_EthernetPortStatisticalData 5-2-20 SMX_EthernetPortControllerSoftwareIdentity SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity.
Property Name ClassificationDescriptions Classifications Property Implementation Ethernet Port Controller Driver 2 (Driver) HPQ:SMX_EthernetPortControllerSoftwareIdentity: InstanceID Manufacturer VersionString 5-2-21 Manufacturer Driver Version SMX_EthernetPortControllerFirmwareIdentity SMX_EthernetPortControllerFirmwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter firmware of the associated Ethernet Port.
Property Name ClassificationDescriptions Classifications InstanceID Property Implementation Ethernet Port Controller Firmware 10 (firmware) HPQ:SMX_EthernetPortControllerFirmwareIdentity: CIM:SoftwareFamily IdentityInfoType HPQ:PCI Vendor Id:DeviceId IdentityInfoValue[0] PCI Vendor Id:Device Id TargetType Manufacturer VersionString 5-2-22 Manufacturer Firmware Version SMX_EthernetElementSoftwareIdentity SMX_EthernetElementSoftwareIdentity implements the class CIM_ElementSoftware
5-2-23 SMX_EthernetElementFirmwareIdentity SMX_EthernetElementFirmwareIdentity implements the class CIM_ElementSoftwareIdentity. It represents the association between SMX_EthernetPortController and SMX_EthernetPortControllerFirmwareIdentity.
Property Name Property Implementation HPQ:SMX_EthernetCollection-1 InstanceID HP_GroupSystemSpecificCollection GroupOperationalStatus 0 (Unknown) 2 (OK) 3 (Degraded) 6 (Error) GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: Unknown OK Degraded Error HP_EthernetCollection 5-2-25 SMX_EthernetMemberOfCollection SMX_EthernetMemberOfCollection associates Ethernet Ports to the Ethernet Collection.
5-2-26 SMX_EthernetGroupHostedCollection SMX_EthernetGroupHostedCollection associates the Ethernet Collection to the Computer System. Property Name Property Implementation CIM_Dependency ref:SMX_ComputerSystem Antecedent ref:SMX_EthernetCollection Dependent CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection 5-2-27 SMX_EthernetTeam SMX_EthernetTeam models Ethernet Redundancy Sets (Ethernet Teams).
Property Name Key:InstanceId Property Implementation System GUID for the team. CIM_RedundancySet LoadBalanceAlgorithm 0 (None) 1 (Other) 3 (Round Robin) MaxNumberSupported Number of ports configured in team. MinNumberNeeded 1 OtherLoadBalanceAlgorithm When LoadBalanceAlgorithm is 1 (Other), OtherLoadBalanceAlgorithm is set to configured Load Balance Algorithm. For example: Automatic RedundancyStatus 2 (Fully Redundant) 3 (Degraded Redundancy) 4 (Redundancy Lost) 5 (Overall Failure).
Property Name TeamCapabilities[] Property Implementation Capabilities of an Ethernet Team. Refer to Windows Ethernet Teaming mof, HP_WinEthRedundancySet.mof For example: Fast Path Failover Current operating mode of the Ethernet Team. TeamCurrentOperatingMode For example: 802.3ad Dynamic With Fault Tolerance Currently enabled capabilities of the Ethernet Team TeamEnabledCapabilities[] TeamOperatingMode 5-2-28 For example: Fast Path Failover Operating modes of an Ethernet Team.
Property Name Property Implementation 1002 (Standby – Spare) 5-2-29 SMX_HostedEthernetTeam SMX_HostedEthernetTeam associates the Ethernet Teams to the containing Computer System. Property Name Property Implementation CIM_OwningCollectionElement Key:OwnedElement ref:HP_EthernetTeam Key:OwningElement ref:HP_ComputerSystem HP_HostedEthernetTeam 5-2-30 SMX_EthernetTeamToLANEndpoint SMX_EthernetTeamToLANEndpoint associates the Ethernet Teams to the Ethernet LAN Endpoints.
Property Name Property Implementation Caption HP Ethernet Event Provider configurable settings Description HP Ethernet Event Provider configurable settings ElementName HP Ethernet Event Provider configurable settings InstanceId 0 HP_EthEventSettings SMX_EthEventSettings ActiveAdapterCountChanged If enabled, an event is generated when a change is detected in number of active adapter count of a team. Default, disabled.
Property Name Property Implementation MonitorLANEndpoints If enabled, events related to SMX_EthernetLANEndpoint are generated. Default, disabled. MonitorPorts If enabled, events related to SMX_EthernetPort are generated. Default, enabled. MonitorRedundancySets If enabled, events related to SMX_EthernetTeam are generated. Default, true. PolInterval The longest interval between network status polls, in seconds. Value 0 disables polling and is not recommended.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name ProbableCauseDescription 5-3-2 Property Implementation Network Interface Lost Connectivity HP_AlertIndication: Network Interface Connectivity Restored Property Name Property Implementation CIM_Indication PerceivedSevertiy 2 (Information) CIM_Alertindication Description If the Network Interface is an Ethernet Port, the Ethernet Port has transitioned from Error to OK.
Property Name Property Implementation CIM_Alertindication Description An Ethernet team's redundancy status changed to Redundancy Lost. All members of an Ethernet team, except one, are failed. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting lost redundancy AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 5 ProviderName HP Ethernet RecommendedActions Check the Ethernet Team and Ethernet Team Member status.
Property Name Property Implementation EventID 6 ProviderName HP Ethernet RecommendedActions No action is recommended HP_AlertIndication Summary Ethernet team redundancy increased EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet team)) ProbableCause 1 (Other) ProbableCauseDescription Ethernet Team Redundancy Increased 5-3-5 HP_AlertIndication: Ethernet Team Redundancy Decreased Property Name Property Implementation CIM_Indication PerceivedSevertiy 3 (Warning) CIM_Alertind
Property Name Property Implementation ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Ethernet Team Redundancy Decreased 5-3-6 HP_AlertIndication: Ethernet Team Redundancy Restored Property Name Property Implementation CIM_Indication PerceivedSevertiy 2 (Information) CIM_Alertindication Description An Ethernet team's redundancy status changed to Fully Redundant. An Ethernet team member status changed from Error or Degraded to OK.
Property Name PerceivedSevertiy Property Implementation 2 (Information) CIM_Alertindication Description An Ethernet team member's status has changed. This is an optional indication that can be disabled via the Ethernet Event Provider settings. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting a member status change.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 9 ProviderName HP Ethernet RecommendedActions Check the Ethernet Team and Ethernet Team Member status. View the System Event Log for additional information. HP_AlertIndication Summary Ethernet Team Member Reported Role Change.
Property Name Property Implementation Summary Ethernet Team Member Dropped from Team.
5-3-11 HP_AlertIndication: Network Interface No Longer Available Property Name Property Implementation CIM_Indication PerceivedSevertiy 3 (DegradedWarning) CIM_Alertindication Description A network interface is no longer available. An Ethernet adapter was removed or an Ethernet team or VLAN was removed via the HP Network Configuration Utility (NCU). AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting network interface no longer available.
Property Name Property Implementation optional indication that can be disabled via the Ethernet Event Provider settings. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting network interface available. AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 11 ProviderName HP Ethernet RecommendedActions No action is recommended.
Property Name RecommendedActions Property Implementation Check the Ethernet Team and Ethernet Team Member status. View the System Event Log for additional information. HP_AlertIndication Summary Ethernet team reported change in number of active members.
6 HP Insight Manager WBEM Fibre Channel Host Bus Adapter Description The HP Insight Management Web-Based Enterprise Management (WBEM) Fibre Channel Host Bus Adapter Profile describes the behavior of Fibre Channel host adapters supporting the SCSI (Fibre Channel Protocol) command set. A Fibre Channel (FC) adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports. A single system can contain one or more HBAs.
Insight Management WBEM support. 6-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_FCHBAProductPhysicalComponent • SMX_FCHBASystemPackaging • SMX_FCHBAGroupHostedCollection • SMX_FCHBAFCPortGroupSystemSpecific • SMX_FCHBALocation • SMX_FCHBAPhysicalElementLocation The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_Systems CreationClassName SMX_FCHBAComputerSystem NameFormat Other CIM_ComputerSystem Dedicated 0 IdentifyingDescriptions[0] HPQ:GUID OtherIdentifyingInfo[0] GUID 6-2-2 SMX_FCHBAFCPort Class The SMX_FCHBAFCPort class implements the HPFCHBA_FCPort class is used to represent a FC port device.
Property Name Value Unknown OK-Online Stopped Offline StatusDescriptions[0] Stopped Bypassed Stopped Diagnostics Stopped Link down Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAFCPort DeviceID Opaque value. SystemName Opaque value.
Property Name Value Other Not present Fabric Public Loop FL Port OtherPortType Fabric Port Fabric expansion port Generic Fabric Port Private Loop Point to Point PortType 1 (Other) One of (in Bits per Second): 0 1000000000 Speed 2000000000 10000000000 UsageRestriction 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) PermanentAddress Port WWN PortNumber Port number. SupportedMaximumTransmissionUnit Port maximum frame size.
Property Name ElementName Value Product Name CIM_ManagedSystemElement NodeWWN Name CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAPortController Node WWN:SerialNumber: DeviceID Where: is the port controller instance number for the same adapter.
Property Name Value InstanceID Opaque SampleInterval 0 CIM_NetworkPortStatistics BytesTransmitted HBAAPI_PORTSTATISTICS.TxWords BytesReceived HBAAPI_PORTSTATISTICS.RxWords PacketsTransmitted HBAAPI_PORTSTATISTICS.TxFrames PacketsReceived HBAAPI_PORTSTATISTICS.RxFrames CIM_FCPortStatistics CRCErrors HBAAPI_PORTSTATISTICS.InvalidCRCCount DumpedFrames HBAAPI_PORTSTATISTICS.DumpedFrames ErrorFrames HBAAPI_PORTSTATISTICS.ErrorFrames InvalidTransmissionWords HBAAPI_PORTSTATISTICS.
Property Name Value CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat WWN SMX_FCHBAPhysicalPackage ClassSMX_FCHBAPhysicalPackage class represents the physical elements of the associated FC port controller. The following table lists the properties implemented.
Property Name Value NodeWWN: Tag Where: is the port controller instance number for the same adapter Version Board Version or N/A when not available CIM_PhysicalPackage RemovalConditions 6-2-6 2 (Not Applicable) SMX_FCHBAProduct Class The SMX_FCHBAProduct class is used to aggregate physical element of the FC HBA. The following table lists the properties implemented and the HBAAPI_ADAPTERATTRIBUTES prefix refers to the HBA API HBA_ADAPTERATTRIBUTES structure.
Property Name Value CIM_ManagedElement Caption FCHBA Driver Device Driver Description ElementName Where: is the product name of the HBA.
Property Name Value CIM_ManagedSystemElement NodeWWN Name CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FCHBA Firmware Classifications 10 (firmware) HPQ:NodeWWN: InstanceID Where: is the port controller instance number for the same adapter Manufacturer Manufacturer SerialNumber Serial number VersionString Firmware version 6-2-9 SMX_FCHBAFirmwareIdentityBIOS Class The SMX_FCHBAFirmwareIdentityBIOS class represents adapter BIOS associated with t
Property Name Value ClassificationDescriptions FCHBA Option ROM Classifications 11 (bios/fc) HPQ:NodeWWN: InstanceID Where: is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString BIOS Version as reported by HBA TargetTypes HBA BIOS UNKNOWN SerialNumber Serial Number MajorVersion 0 MinorVersion 0 RevisionNumber 0 HP_SoftwareIdentity 6-2-10 SMX_FCHBAGroupSystemSpecificCollection Class The SMX_FCHBAGroupSystemSpecif
Property Name Value HP_GroupSystemSpecificCollection 0 (Unknown) 1 (Other) GroupOperationalStatus[0] 2 (OK) 3 (Degraded) 6 (Error) 10 (Stopped) Unknown Other OK GroupStatusDescriptions[0] Degraded Error Stopped 6-2-11 SMX_FCHBAComputerSystemFCPort Class The SMX_FCHBAComputerSystemFCPort class is used to represent an association between SMX_ComputerSystem and HPFCHBA_FCPort. The following table lists the properties implemented.
Property Name Value CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemPortController GroupComponent Refer to SMX_FCHBAComputerSystem class properties. PartComponent Refer to SMX_FCHBAPortController class properties. 6-2-13 SMX_FCHBAComputerSystemLogicalPortGroup Class The SMX_FCHBAComputerSystemLogicalPortGroup class is used to represent an association between SMX_ComputerSystem and SMX_FCHBALogicalPortGroup. The following table lists the properties implemented.
Property Name Value InstalledSoftware Refer to SMX_FCHBASoftwareIdentityDrv class properties. System Refer to SMX_FCHBAComputerSystem class properties. 6-2-15 SMX_FCHBAFCPortFCPortStatistics Class The SMX_FCHBAFCPortFCPortStatistics class is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Value CIM_Dependency CIM_ControlledBy SMX_FCHBAPortControllerFCPort Antecedent Refer to SMX_FCHBAPortController class properties. Dependent Refer to SMX_FCHBAFCPort class properties. 6-2-18 SMX_FCHBAPhysicalPackagePortController Class The SMX_FCHBAPhysicalPackagePortController class is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAPhysicalPackage. The following table lists the properties implemented.
SMX_FCHBASoftwareIdentityDrvPortController Antecedent Refer to SMX_FCHBASoftwareIdentityDrv class properties. Dependent Refer to SMX_FCHBAPortController class properties. 6-2-20 SMX_FCHBAPortControllerFirmwareIdentityFW Class The SMX_FCHBAPortControllerFirmwareIdentityFW class is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFirmwareIdentityFW. The following table lists the properties implemented.
6-2-22 SMX_FCHBAProductPhysicalComponent Class The SMX_FCHBAProductPhysicalComponent class is used to represent an association between SMX_FCHBAProduct and SMX_FCHBAPhysicalPackage. The following table lists the properties implemented. Property Name Value CIM_Component CIM_ProductPhysicalComponent SMX_FCHBAProductPhysicalComponent GroupComponent Refer to SMX_FCHBAProduct class properties. PartComponent Refer to SMX_FCHBAPhysicalPackage class properties.
Property Name Value CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection SMX_FCHBAGroupHostedCollection Antecedent Refer to SMX_ComputerSystem class properties. Dependent Refer to SMX_FCHBAGroupSystemSpecificCollection class properties. 6-2-25 SMX_FCHBAFCPortGroupSystemSpecific Class The SMX_FCHBAFCPortGroupSystemSpecific class is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAGroupSystemSpecificCollection.
Property Name Value NodeWWN:SerialNumber: Where: is the port controller instance number for the same adapter. Name HP_Location ElementLocationTag ElementLocationTagDesc Refer to “Physical Location” for more information. 1 (slot) PhysicalPosition 6-2-27 Refer to “Physical Location” for more information.
Property Name OperationalStatus[0] Value 0 (Unknown) 2 (OK-Online) 6 (Error) 10 (Stopped) 11 (In Service) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreatingClassName SMX_FCHBASCSIProtocolController DeviceID PortWWN SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolController MaxUnitsControlled 255 CIM_SCSIProtocolController 6-2-29 SMX_FCHBASC
Property Name Value EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreatingClassName SMX_FCHBASCSIProtocolEndpoint SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolEndpoint 57 (HIPPI Interface) ProtocolFType CIM_SCSIProtocolController ConnectionType 2 (fibre channel) Role 2 (initiator) 6-2-30 SMX_FCHBAComputerSystemSCSIProtocolController SMX_FCHBAComputerSystemSCSIProtocolController is used to represent an associatio
Property Name Value SMX_FCHBAFCPortSCSIProtocolEndpoint Antecendent ref:SMX_FCHBAPort Dependent ref:SMX_FCHBASCSIProtocolEndpoint 6-2-32 SMX_FCHBASCSIProtocolControllerFCPort SMX_FCHBASCSIProtocolControllerFCPort is used to represent an association between SMX_FCHBASCSIProtocolController and SMX_FCHBAFCPort.
Property Name Value CIM_LogicalIdentity CIM_ConcreteIdentity SMX_FCHBAConcreteIdentity SystemElement ref:SMX_ComputerSystem SameElement ref:SMX_ FCHBAComputerSystem 6-3 Physical Location The Physical Location is a string representing the physical location of the Fibre Channel Host Bus Adapter device. This string should represent the physical location of the device with which an end-user can uniquely locate the device.
7 HP Insight Manager WBEM Host File System Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Host Filesystem provider and extends CIM classes described in this document to model the filesystems hosted by a managed node. These classes provide computational information and capabilities that serve as an aggregation point to associate one or more elements that make up hosted filesystems and logical disks.
Schema Supported by the Provider This provider supports the following classes: • SMX_LocalFileSystem • SMX_HostedLocalFileSystem • SMX_LocalLogicalDisk • SMX_LocalFSResidesOnExtent The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation OS path name to filesystem root location. Root For example: /home/users AvailableSpace Total amount of free space for the filesystem in bytes. Unknown = 0. BlockSize Read/write data block size in bytes. FileSystemSize Total size of the filesystem in bytes. Unknown = 0. String describing the type of filesystem.
Property Name Property Implementation CIM_ManagedElement CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName CreationClassName SMX_LocalLogicalDisk Path to logical disk. DeviceID For example: /dev/cdrom1 CIM_StorageExtent BlockSize Read/write data block size in bytes.
7-2-4 SMX_LocalFSResidesOnExtent Class The SMX_LocalFSResidesOnExtent class implements the CIM_ResidesOnExtent class and associates the SMX_LocalFileSystem and SMX_LocalLogicalDisk instances. The following table lists the properties implemented.
8 HP Insight Management WBEM IML Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Integrated Management Log (IML) provider implements the server management record log. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.
Schema Supported by the Provider This provider supports the following classes: • SMX_IMLRecordLog • SMX_IMLLogEntry • SMX_IMLLogManagesRecord • SMX_IMLUseOfLog The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation OperationalStatus[0] indicates the highest severity of IML log entries and will contain one of the following: OperationalStatus 2 (OK), only informational or repaired events exist in the IML log 3 (Degraded), at least one degraded event exists in the IML log 6 (Error), at least one critical event exists in the IML log StatusDescriptions[0] will contain one of the following corresponding to OperationalStatus[0]: StatusDescriptions IML log has no critical or degraded
Property Name TimeOfLastChange Property Implementation Time of last log change. The following table lists the methods implemented for the SMX_IMLRecordLog class. Method Name Method Implementation ClearLog Refer to HP Record Log profile (P00109) RepairAll Refer to HP Record Log profile (P00109). 8-2-2 SMX_IMLLogEntry Class The SMX_IMLLogEntry class implements the HP_CommonLogEntry class to model logs records within the IML log. The following table lists the properties implemented.
Property Name Property Implementation HP_CommonLogEntry RecordDataType 3 (Delimited) RawData IML log event raw data. MajorClass 18 (IML) MinorClass 2 (None) UpdateTimestamp IML log event update time stamp. OccurrenceCount Number of occurrences of this same IML event type. 0 (Unknown) 2 (Information) Severity 3 (Repaired) 4 (Degraded/Warning) 7 (Critical) 0 (Unknown) OSType 36 (Linux) 39 (VMware) SystemSerialNumber System serial number string from SMBIOS.
Method Name Refer to HP Record Log profile (P00109). Repair 8-2-3 Method Implementation SMX_IMLLogManagesRecord Class The SMX_IMLLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of SMX_IMLRecordLog and SMX_IMLLogEntry. The following table lists the properties implemented.
9 HP Insight Management WBEM IPMI Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Intelligent Platform Management Interface (IPMI) Record Log provider supports system logs available on HP servers. These logs are called the System Event Log (SEL) and the Forward Progress Log (FPL) and contain informational, warning, and critical event information about a server’s performance and sensors.
9-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_FPLRecordLog • SMX_FPLLogEntry • SMX_FPLLogManagesRecord • SMX_FPLUseOfLog • SMX_SELRecordLog • SMX_SELLogEntry • SMX_SELLogManagesRecord • SMX_SELRecordLogIndication • SMX_SELUseOfLog The tables in the following sections describe the properties of the supported classes.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption FPL record log Description Forward Progress Log ElementName FPL record log CIM_ManagedSystemElement Name FPL record log OperationalStatus OperationalStatus[0] indicates whether the FPL log is in good health and accepting new FPL entries.
Property Name Property Implementation CIM_RecordLog InstanceID HPQ:SMX_FPLRecordLog:1 HP_CommonRecordLog TimeOfLastChange Time of last log change The following table lists implemented methods for the SMX_FPLRecordLog class. Method Name Method Implementation ClearLog See the HP Record Log profile. RepairAll See the HP Record Log profile. 9-2-2 SMX_FPLLogEntry Class The SMX_FPLLogEntry class implements the HP_CommonLogEntry class to model logs records within the FPL log.
Property Name Property Implementation HP_CommonLogEntry RawData FPL log event raw data array MajorClass 11 (FPL) MinorClass 2 (None) System serial number string from SMBIOS. SystemSerialNumber For example: USE4822L0H System model number string from SMBIOS. SystemModel For example: server rx6600 SystemName Computer system name. LoggerType 2 (Server) The following table lists implemented methods for the SMX_FPLLogEntry class. Method Name See the HP Record Log profile.
9-2-4 SMX_FPLUseOfLog Class The SMX_FPLUseOfLog class implements the HP_UseOfLog class and associates the instance of HP_ComputerSystem with the instance of HP_CommonRecordLog. The following table lists the properties implemented.
Property Name StatusDescriptions Property Implementation StatusDescriptions[0] will contain the following value corresponding to OperationalStatus[0]: OK HealthState 5 (OK), when OperationalStatus[0]=2 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 5 (Not Applicable) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords Number of records available in NVRAM.
9-2-6 SMX_SELLogEntry Class The SMX_SELLogEntry class implements the HP_CommonLogEntry class to model logs records within the SEL log. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement SEL record log entry Caption Where: RecordID is the SMX_SELLogEntry.RecordID for the event. Description Same as Caption. ElementName Same as Caption.
Property Name LoggerType Property Implementation 2 (Server) The following table lists implemented methods for the SMX_SELLogEntry class. Method Name See the HP Record Log Profile. Repair 9-2-7 Method Implementation SMX_SELLogManagesRecord Class The SMX_SELLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of HP_RecordLog and HP_LogEntry. The following table lists the properties implemented.
Dependent 9-3 References SMX_ComputerSystem Provider Indications 9-3-1 SMX_SELRecordLogIndication Class The SMX_SELRecordLogIndication class implements and extends the HP_CommonRecordLogIndication class to Alert Clients to to new WBEM events found in the SEL Record log.
Property Name Property Implementation For example: 02.03.10 NetworkAddresses Contains a list of all the IP addresses or hostname of the computer system generating the indication. OSType On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: , , ProbableCause 0 (Unknown) ProbableCauseDescription Short text describing cause if known.
Property Name Property Implementation 0 (Unknown) PerceivedSeverity 3 (Degraded/Warning) 6 (Critical) RecordLogInstanceID Opaque Record Log key. LogEntryInstanceIDs Array of length 1 containing an opaque Log Entry key. SMX_SELRecordLogIndication RawData Array if 14 bytes of raw event data.
Property Name Property Implementation Value will contain hex string representation of SystemGUID 8-Byte Physical Location blob represented as a string HWPhysicalLocation For example: “00-ff-ff-ff-ff-05-ff-64” HP Insight Management WBEM IPMI Record Log Provider Overview 176
10 HP Insight Management WBEM Management Processor Lite Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Processor Lite provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Management Processor (MP) Lite Profile HP WBEM TC 2.0.
10-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_ManagementProcessor • SMX_MPFirmware • SMX_MPCollection • SMX_MPHostedCollection • SMX_MPComponentCS • SMX_MPMemberOfCollection • SMX_MPElementFirmwareIdentity • SMX_MPInstalledFirmwareIdentity The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation Short Description of the Management Processor, including the product name and the enabled state of the MP. For example: Product name of the management processor in the format: (X) Caption Where: is the name of the MP product and (X) indicates whether the MP is Active or Inactive/Disabled.
Property Name Property Implementation Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor Lite Profile for specific descriptions of when each value is populated).
Property Name Property Implementation 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), normal operation 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) 20 (Major failure), when OperationalStatus[0]=6 (Error) HealthState Note: When a Management Processor is disabled (refer to property EnabledState) HealthState will always report a state of 5 (OK) so as not to contribute negatively to overall system status.
Property Name Property Implementation Enumerator indicating the model or type of management processor.
Property Name Property Implementation Enumerator indicating the condition of the MP-resident network interface connection. 0 (Unknown) 2 (OK) 3 (NIC disabled) NICCondition 4 (NIC not in operation-alternate host NIC in use) 5 (NIC in operation but disconnected) 6 (Failed) Note: When a Management Processor is disabled (refer to property EnabledState) NICCondition will always report a state of 3 (NIC disabled ). Network communication with the MP is not possible when the MP is disabled.
Property Name Property Implementation gateways for the management processor HostName The network hostname in use by this management processo,rif one is defined HP_ManagementProcessor 10-2-2 SMX_MPFirmware Class The SMX_MPFirmware class implements the HP_MPFirmware class to describe management processor firmware The following table lists the properties implemented.
Property Name Property Implementation HPQ:SMX_MPFirmware:1 MajorVersion The major version of the MP firmware. MinorVersion The minor version number of the MP firmware. VersionString String indicating the MP firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties.
Property Name Description Property Implementation Description of the class, for example HP Management Processor Collection ElementName for the class ElementName For example: Management Processor Collection CIM_Collection CIM_SystemSpecificCollection Opaque instance identifier using HPQ as the OrgID.
Property Name Property Implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_MPHostedCollection Antecedent References HP_ComputerSystem Dependent References HP_MPCollection 10-2-5 SMX_MPComponentCS Class The SMX_MPComponentCS class implements the HP_MPComponentCS class to associate a management processor subsystem to the scoping computer system that contains it. The following table lists the properties implemented.
Property Name Property Implementation FALSE—Do not include member status in collection status Collection References HP_MPCollection Member References HP_ManagementProcessor 10-2-7 SMX_MPElementFirmwareIdentity Class The SMX_MPElementFirmwareIdentity class implements the HP_MPElementFirmwareIdentity class to associate a management processor to its corresponding firmware. The following table lists the properties implemented.
11 HP Insight Management WBEM PCI Device Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) PCI Device provider implements the profiles listed to support PCI devices installed on HP servers. The following table details the profiles implemented and files installed by this provider Implemented Profiles •DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 •DMTF: Physical Asset Profile •HP: Location Profile 1.
• SMX_PCISlot • SMX_PCICardInSlot • SMX_RealizesPCIDevice • SMX_SystemPCISlot • SMX_SystemPCIDevice • SMX_PCISlotLocation • SMX_PCISlotElementLocation The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation Description A user-friendly description for this PCI device provided by the operating system. ElementName A hardware ID for this PCI device provided by the operating system. CIM_ManagedSystemElement Name A hardware ID for this PCI device provided by the operating system. CIM_LogicalDevice CreationClassName “SMX_PCIDevice” DeviceID Unique identifier for this PCI device instance. SystemCreationClassName SMX_ComputerSystem.
Property Name Property Implementation Revision Revision ID as described in the configuration registers for this PCI device. SubClassCode Register of 8 bits that identifies with further granularity the subclass of the PCI device. This property is only the middle byte (bit offset 08h) of the 24-bit ClassCode register. Note the meaning of this property is interpreted based on the value of the ClassCode byte. SubsystemID Subsystem ID as described in the configuration registers for this PCI device.
Property Name Property Implementation VendorCompatibilityStrings “HPQ:PCICard” CIM_Card HostingBoard False HP_PCICard 11-4-3 SMX_PCISlot Property Name Property Implementation CIM_ManagedElement Caption Same as Name. CIM_ManagedSystemElement “PCI” Name Refer to “Physical Location” for more information. CIM_PhysicalElement CreationClassName “SMX_PCISlot” Tag Opaque Key. HPQ:SMX_PCISlot: Description Same as Name. ElementName Same as Name.
Property Name Property Implementation 43 (PCI) – if this is a 33 MHz PCI slot ConnectorType 80 (PCI-66MHZ) – if this is a 66 MHz PCI slot 98 (PCI-X) – if this is a PCI-X slot 1 (Other) – if this is a PCI Express slot Only initialized if ConnectorType == 1 (Other): ConnectorDescription “PCI Express” – if this is a PCI Express slot or “PCI Express Mezzanine” if mezzanine slot in a blade, otherwise this property is not set OtherTypeDesciption Deprecated in favor of ConnectorDescription CIM_Slot The phys
Property Name Property Implementation GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_PCISlot 11-4-7 SMX_SystemPCIDevice Property Name Property Implementation GroupComponent References SMX_ComputerSystem PartComponent References SMX_PCIDevice 11-4-8 SMX_PCISlotLocation Property Name Property Implementation CIM_ManagedElement Caption Same as ElementLocationTag. Description Same as ElementLocationTag. ElementName Same as ElementLocationTag.
Property Name Property Implementation Additional enumerators for Cellular servers 7 (Cabinet) 6 (Chassis) Additional enumerators for HP BladeSystem servers 14 (Blade) 1 (Mezzanine) LocationInformation Array of text values representing the location components that describe this PCI Slot location. LocationInfoDesc[0] per LocationInfornation[0].
11-6 Provider Indications Indications Generated by the Provider This provider generates no indications.
12 HP Insight Management Power Supply Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Power Supply provider implements the HP Power Supply profile to model power supplies in servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Power Supply Profile HP WBEM TC 1.3 (P103) HP Location Profile HP WBEM TC 1.0 (P124) HP Power Supply Physical Asset Profile HP WBEM TC 1.
12-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
how the provider determines the properties implementation. When the property implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis. If other values are returned, a problem is indicated. Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems.
Property Name Property Implementation 2 (OK) – if power supply is operating properly; OperationalStatus[0] 3 (Degraded) – if power supply is degraded; 6 (Error) – if power supply has failed OperationalStatus[1] Extended Warning and Error status. See the MOF and Profile Description of the status of the power supply corresponding to the OperationalStatus.
Property Name Property Implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PowerSupply TotalOutputPower 0 (denotes ‘unknown’) HP_PowerSupply PowerSupplyType 12-2-2 Enumeration describing the type of power supply. Refer to the Managed Object Format. SMX_PowerCollection Class The SMX_PowerCollection class is used to model power supply collections on servers. There is one instance of this class on servers modeling power supplies.
Property Name Property Implementation Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown) – if power collection status is unknown; 2 (OK) – if power supplies are operating properly; 3 (Degraded) – if no SMX_PowerSupply.OperationalStatus[0] for all non-fault tolerant power supplies report 6 (Error) and SMX_PowerRedundancySet.
Property Name Property Implementation Power Redundancy Set Where: represents the number of the redundancy set instance. Description of this redundancy set Description For example: Power Redundancy Set is collection of fault tolerant power supplies that provide redundant power Where: represents the number of the redundancy set instance. User printable name for this power redundancy set.
The following table lists the properties implemented.
12-2-7 SMX_HostedPowerCollection Class The SMX_HostedPowerCollection class is used to represent an association between the HP_PowerCollection class and the computer system that contains this collection. The following table lists the properties implemented.
Property Name Property Implementation Description of this power supply location, including the location. Description For example on HP Proliant: The location of the power supply . Please refer to power supply position printed on the system. Where: presents the power supply position printed on the system labeling. User displayable name of this power supply location, including the location.
Property Name PhysicalLocation 12-2-11 Property Implementation References CIM_Location SMX_PowerSupplyModule Class The SMX_PowerSupplyModule class is used to model physical power supplies on servers. Power supply numbers for existing instances do not change when other power supplies are added and removed. The following table lists the properties implemented.
Property Name Property Implementation Description of the status of the power supply corresponding to the OperationalStatus.
Property Name Property Implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_PowerSupplyModule 12-2-13 SMX_RealizesPowerSupply Class The SMX_RealizesPowerSupply class extends the CIM_Realizes class and associates the HP_PowerSupply instance with HP_PowerSupplyModule instances. The following table lists the properties implemented.
Property Name Property Implementation StatusDescriptions[0] Power supply slot is operating properly – if OperationalStatus[0] is 2 (OK) HealthState 5 (OK) – if power supply is operating properly Name of the power supply slot. Name For example: PowerSupplySlot=2 CIM_PhysicalElement CreationClassName SMX_PowerSupplySlot Tag Unique identifier for this power supply slot. CIM_PhysicalPackage ConnectorLayout 6 (Slot) Number 12-2-15 Where: represents the number of the power supply slot.
Antecedent References HP_PowerSupplySlot Dependent References HP_PowerSupplyModule 12-2-17 SMX_Power Meter SMX_PowerMeter is used to model power utilization on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Not all systems support reporting power utilization .
Property Name Property Implementation PowerSupplySlot=1. CIM_LogicalDevice: CreationClassName SMX_PowerMeter DeviceID Unique identifier for this power utilizaton sensor. SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SMX_ComputerSystem.
Property Name Property Implementation GroupComponent References HP_ComputerSystem PartComponent References HP_PowerMeter 12-2-19 SMX_AssociatedPowerMeter The SMX_AssociatedPowerMeter class associates the HP_PowerSupply instance with HP_PowerMeter instance.
Property Name Property Implementation HealthState 5 (OK) Name Power controller firmware.
Property Name Property Implementation System References HP_ComputerSystem InstalledSoftware References HP_PowerControllerFirmware 12-3 Provider Indications Indications Generated by the Provider The following tables describe the SMX WBEM Power Supply Provider indications that are implemented for HP ProLiant server platforms where available. HP Integrity server platforms implement power supply related indications in the SMX IPMI Record Log provider.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: major.minor.build SystemFirmwareVersion Array of firmware versions of the computer system generating the indication. SystemSerialNumber Serial number of the computer system generating the indication. SystemProductID Product ID of the computer system generating the indication. SystemModel Model name of the computer system generating the indication.
Property Name Property Implementation AlertType 5 (Device Alert) EventID “9” ProviderName “HP Power” RecommendedActions “Check the input power being supplies to the failed power supply and reconnect power.” HP_AlertIndication Summary “Power supply failed – input power lost“ EventCategory 16 (System Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription “Power Supply Failed due to input power loss.
Property Name Property Implementation EventCategory 16 (System Power) ProbableCause 1 (Other) ProbableCauseDescription Power Supply Removed 12-3-4 HP_DeviceIndication: Power Supply Inserted Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A power supply has been inserted. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has been inserted.
Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A power supply has failed. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has failed. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the failed power supply.
Property Name Property Implementation Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has degraded. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the degraded power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 20 ProviderName HP Power RecommendedActions Check the degraded power supply and replace if necessary.
Property Name Property Implementation ProviderName HP Power RecommendedActions No action is recommended. Summary Power supply repaired EventCategory 16 (System Power) ProbableCause 1 (Other) ProbableCauseDescription Power supply repaired HP_DeviceIndication: Power Supply Redundancy Reduced 12-3-8 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fault tolerant power supply is no longer providing power for a power redundancy set.
Property Name ProbableCause Property Implementation 88 (Loss of Redundancy) ProbableCauseDescription Power Redundancy has been Reduced 12-3-9 HP_DeviceIndication: Power Supply Redundancy Lost Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication Power redundancy has been lost. RedundancySetCaption Description Where: RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set that lost redundancy.
12-3-10 HP_DeviceIndication: Power Supply Redundancy Failed Important: This indication is not supported on HP Proliant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Power redundancy has been lost. RedundancySetCaption Description Where: RedundancySetCaption represents the SMX_PowerRedundancySet.
Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Power redundancy for the system has been restored. RedundancySetCaption Description Where: RedundancySetCaption is SMX_PowerRedundancySet.Caption of the redundancy set the power redundancy set with restored redundancy. AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance representing the power redundancy set with restored redundancy.
13 HP Insight Management WBEM Profile Registration Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Profile Registration provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Profile Registration Profile (P00100) HP WBEM TC 1.0.
Schema Supported by the Provider This provider supports the following classes: • SMX_RegisteredProfile • SMX_ExtendsProfile • SMX_ReferencedProfile • SMX_PRPBaseServerECTP The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name AdvertiseTypes Property Implementation 3 (SLP) HPQ: InstanceID Where: : is a unique number. NULL for DMTF profiles OtherRegisteredOrganization None for SNIA SMI-S storage profiles. "HP WBEM TC" for HP extension profiles. RegisteredName The DMTF Profile table lists the property values for this class.
Registered Version RegisteredName Caption/Description/ElementName Software Inventory 1.0.0 DMTF Software Inventory Profile Profile Registration 1.0.0 DMTF Profile Registration Profile The following table lists all possible SNIA Profiles. Some implementations only support a subset of these profiles so only the subset is reported. RegisteredName Registered Version Caption/Description/ElementName Block Services 1.3.0 SNIA Block Services Profile Disk Drive Lite 1.3.
RegisteredName Registered Version Caption/Description/ElementName Asset HP CPU Physical Asset 1.0.0 HP CPU Physical Asset Profile HP Memory Physical Asset 1.0.0 HP Memory Physical Asset Profile HP Fan Physical Asset HP Fan Physical Asset Profile 1.0.0 HP Power Supply Physical 1.0.0 Asset HP Power Supply Physical Asset Profile HP CPU Consolidated Status 1.0.0 HP CPU Consolidated Status Profile HP Sensors 1.0.0 HP Sensors Profile HP Record Log 1.0.
Dependent 13-2-3 References HP_RegisteredProfile (extends) SMX_ReferencedProfile Class The SMX_ReferencedProfile class extends the CIM_ ReferencedProfile class and associates an HP profile that references another profile when both are registered in the root\Interop namespace. The following table lists the properties implemented.
14 HP Insight Management WBEM System Temperature Sensor Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management System Temperature Sensor provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Sensor Profile HP WBEM TC 1.
Schema Supported by the Provider This provider supports the following classes: • SMX_NumericSensor • SMX_SensorCollection • SMX_SystemSensor • SMX_HostedSensorCollection • SMX_MemberOfSensorCollection The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation the number of the temperature sensor instance, NumericSensorType represents the value of NumericSensorTypeand StatusDescription represents the value of StatusDescriptions[0]. “Temperature Sensor ” ElementName Where: is the name displayed by the MP or iLO.
Property Name Property Implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_Sensor SensorType CurrentState 2 (Temperature) Normal – if OperationalStatus[0] is 2 (OK); Critical – if OperationalStatus[0] is 6 (Error); Array can contain any of the following values: PossibleStates PossibleStates[0] = Normal; PossibleStates[1] = Critical; CIM_NumericSensor CurrentReading Current reading of temperature sensor BaseUnits 2 (Degrees C) Rate
Property Name Property Implementation system if the threshold is crossed. HP_NumericSensor Enumeration describing the type of temperature sensor. Refer to the Managed Object Format. NumericSensorType 14-2-2 SMX_SensorCollection Class The SMX_SensorCollection class implements the HP_SensorCollection and is used to model temperature sensor collections on servers. There is one instance of this class on systems modeling sensors. The following table lists the properties implemented.
Property Name Property Implementation Temperatures reported by the sensors are operating within normal operating range if temperatures reported by the sensors are within normal operating range; Temperatures reported by the sensors have exceeded their non-critical threshold and the fans have been GroupStatusDescriptions[0] set to full speed if temperatures reported by the sensors have exceeded their threshold and has set fans to full speed; Temperatures reported by the sensors have exceeded their threshold
14-2-5 SMX_SystemSensor Class The SMX_SystemSensor class implements the HP_SystemSensor class and is used to represent an association between the SMX_NumericSensor class and the computer system that contains the sensor. The following table lists the properties implemented.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Temperature RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. SystemName HP_ComputerSystem.Name SystemCreationClassName HP_ComputerSystem.
Property Name Property Implementation Contains the temperature sensor threshold property name that sets a value: VariableNames UpperThresholdNonCritical UpperThresholdCritical UpperThresholdFatal VariableTypes 9 (sint32) VariableValues SMX_NumericSensor, UpperThresholdNonCritical, UpperThresholdCritical or UpperThresholdFatal property value that is set for the temperature sensor detecting the exceeded threshold.
Property Name IndicationTime Property Implementation Time of indication. CIM_AlertIndication Description A temperature sensor has detected that the temperature has returned to a normal operating range. Where: is the SMX_NumericSensor.Caption for the temperature sensor detecting a recovered exceeded threshold. AlertingManagedElement WBEM Path of SMX__NumericSensor instance representing the temperature sensor detecting a recovered exceeded threshold.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication. SystemSerialNumber Serial number of the computer system generating the indication. SystemProductID Product ID of the computer system generating the indication. SystemModel Model name of the computer system generating the indication. SystemGUID Platform GUID of the computer system generating the indication.
15 HP Insight Management WBEM Smart Array Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Smart Array provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Smart Array Profile (P00121) HP WBEM TC 1.0.
This provider supports the following classes: • SMX_SAArraySystem • SMX_SAArrayController • SMX_SAStorageVolume • SMX_SADiskDrive • SMX_SAStorageExtent • SMX_SADiskDriveFirmware • SMX_SAPhysicalPackage • SMX_SAArrayControllerPhysicalPackage • SMX_SADiskPhysicalPackage • SMX_SAStorageEnclosure • SMX_SAStorageEnclosureProcessor • SMX_SAPortController • SMX_SADAPort • SMX_SASPIPort • SMX_SAFirmware • SMX_SAEnclosureFirmware • SMX_SAPrimordialPool • SMX_SAStoragePool • SMX_S
• SMX_SAArrayControllerLocation • SMX_SAStorageCapabilities • SMX_SAProduct • SMX_SAStorageEnclosureLocation • SMX_SAArraySystemRedundancySet (Association) • SMX_SAStorageVolumeStorageSetting (Association) • SMX_SAPrimordialPoolStorageCapabilities (Association) • SMX_SAStoragePoolStorageCapabilities (Association) • SMX_SAArraySystemStorageEnclosureProcessor (Association) • SMX_SAArraySystemSCSIProtocolController (Association) • SMX_SAArraySystemPortController (Association) • SMX_SAArr
• SMX_SAStorageSpecificCollectionArraySystem (Association) • SMX_SAArrayControllerRedundancySet (Association) • SMX_SAStorageRedundancySetStorageExtent (Association) • SMX_SAArraySystemFirmware (Association) • SMX_SASCSIProtocolControllerStorageVolume (Association) • SMX_SAFirmwareArraySystem (Association) • SMX_SAStorageEnclosureProcessorEnclosureFirmware (Association) • SMX_SADiskDriveDiskDriveFirmware (Association) • SMX_SADiskDriveStorageExtent (Association) • SMX_SADiskPhysicalPackag
• SMX_ISASPortISASSCSIProtocolEndPoint (Association) • SMX_ArraySystemISASSCSIProtocolEndPoint (Association) • SMX_ArraySystemISASPort (Association) • SMX_PortControllerISASPort (Association) • SMX_ArraySystemTSASSCSIProtocolEndpoint (Association) • SMX_TSASPortTSASSCSIProtocolEndpoint (Association) • SMX_ArraySystemTSASPort (Association • SMX_DiskDriveTSASSCSIProtocolEndpoint (Association) • SMX_SCSIInitiatorTargetLogicalUnitPath The tables in the following sections describe the propertie
Property Name Property Implementation the internal identifier for the embedded controller. CIM_ManagedSystemElement Overall status of the Array System and attached devices. This is calculated per the algorithm described in the HP Smart Array Profile. 0 (Unknown) OperationalStatus[0] 2 (OK) 3 (Degraded) 6 (Error) More info for OperationalStatus result. This provides a short Description to identify who is contributing to non-OK status.
Property Name Property Implementation embedded on motherboard. PCISLOT- will be reported if there is no Serial Number for device is local For example: PCI occupies slot. NameFormat Other CIM_ComputerSystem Dedicated[0]: Dedicated 3 (Storage) Dedicated[1]: 15 (Block Server) IdentifyingDescriptions Other Vendor Specific Name Controller Serial Number EMBEDDED- will be reported if there is no Serial Number for device is local OtherIdentifyingInfo For example: embedded on motherboard.
Property Name Property Implementation Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller. CIM_ManagedSystemElement Status for Array Controller.
Property Name Property Implementation ADGSupported See HP Smart Array Profile AcceleratorBackupPowerSource See HP Smart Array Profile BatteryStatus See HP Smart Array Profile CacheBoardPresent See HP Smart Array Profile CacheHasBattery See HP Smart Array Profile CacheParityReadErrors See HP Smart Array Profile CacheParityWriteErrors See HP Smart Array Profile CacheReadPercent See HP Smart Array Profile CacheSerialNumber See HP Smart Array Profile CacheSizeTotal See HP Smart Array Profil
Property Name Property Implementation CIM_ManagedElement Logical drive number with raid Description ElementName For example: Logical Volume 1 (RAID 1+0) CIM_ManagedSystemElement Name VPD Pg83 identifier for the volume.
Property Name NoSinglePointOfFailure NumberOfBlocks Property Implementation True – RAID 1 or above False – RAID 0 Total Number of blocks on the volume. 0 (RAID 0) PackageRedundancy 1 (RAID 1+0, RAID 5) 2 (RAID 6), RAID 50, RAID 60 CIM_Storagevolume NameFormat 2 (VPD83NAA6) HPSA_Storagevolume Accelerator See HP Smart Array Profile Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OperationalStatus[0, 1] Volume status.
Property Name Property Implementation Disk location ElementName For example: Port: 1E Box 1 Bay: 5 CIM_ManagedSystemElement Name Drive Serial Number OperationalStatus[0] Drive status, DMTF defined value is populated in index (0) and extended status is populated in index(1) per HP Smart Array Profile CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SADiskDrive Devi
Property Name Property Implementation NegotiatedSpeed See HP Smart Array Profile Identify() See HP Smart Array Profile 15-2-5 SMX_SAStorageExtent Class The SMX_SAStorageExtent class implements the HPSA_StorageExtent class and represents the consumable storage that is available on a disk drive. There is one instance per disk drive. The following table lists the properties implemented.
Property Name Property Implementation SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name Property Implementation CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]Storage Device VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmware 15-2-7 SMX_SAPhysicalPackage Class The SMX_SAPhysicalPackage class implements the
Model Controller model string PartNumber N/A – Not Available for this implementation SerialNumber Controller Serial number for HBA’s Tag Opaque Key Version N/A – Not Available for this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_PhysicalPackage 15-2-8 SMX_SAArrayControllerPhysicalPackage Class The SMX_SAArrayControllerPhysicalPackage class implements the HPSA_ArrayControllerPhysicalPackage class and represents the physical aspects of any Smart Array controller
PartNumber N/A – Not Available for this implementation SerialNumber Controller Serial number Tag Opaque Key Version N/A – Not Available for this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_ ArrayControllerPhysicalPackage 15-2-9 SMX_SADiskPhysicalPackage Class The SMX_SADiskPhysicalPackage class represents the physical aspects of the disk drive. There is one instance per disk drive. The following table lists the properties implemented.
Property Name Property Implementation N/A – Not Available in this implementation Version CIM_PhysicalPackage HotSwappable RemovalConditions TRUE - Drive is hot swappable FALSE – Drive is not hot swappable 2 (Not Applicable) HPSA_ DiskPhysicalPackage 15-2-10 SMX_SAStorageEnclosure Class The SMX_SAStorageEnclosure class implements the HPSA_StorageEnclosureclass and represents the physical chassis for an internal or externally attached enclosure. The following table lists the properties implemented.
Property Name Property Implementation N/A if not available PartNumber N/A – Not Available in this implementation Enclosure Serial Number. SerialNumber N/A will be reported if there is no serial number (For example: internal enclosures).
Property Name Property Implementation Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows.
Property Name Property Implementation Port Number:BoxNumber enclosure is attached to. OtherIdentifyingInfo[0] For example: 1E:1 HPSA_StorageEnclosureProcessor 15-2-12 SMX_SAPortController Class The SMX_SAPortController class represents the HBA in the host system. There is one instance per HBA. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and . Refer to “Physical Location” for more information.
Property Name Property Implementation CIM_Controller CIM_PortController ControllerType 1 (Other) OtherControllerType SAS/SATA – SAS/SATA HBA HPSA_PortController 15-2-13 SMX_SADAPort Class The SMX_SADAPort class implements the HPSA_DAPort class and represents the front-end port for an HBA in the host system. Direct attached implies that the array controller is attached to a local bus on the host, such as PCI. The following table lists the properties implemented.
Property Name RequestedState Property Implementation 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SADAPort DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_LogicalPort UsageRestriction 2 (Front-End Only) CIM_DAPort HPSA_DAPort 15-2-14 SMX_SAFirmware Class The SMX_SAFirmware class implements the HPSA_Firmware class and represents the firmware installed on a Smart Array controller.
Property Name Property Implementation InstanceID Opaque key Manufacturer Controller Vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue VersionString [1]Storage Controller Controller firmware version string HPSA_Firmware 15-2-15 SMX_SAEnclosureFirmware Class The SMX_SAEnclosureFirmware class implements the HPSA_EnclosureFirmware class and represents the firmware installed on a Smart Array Enclosure.
Property Name Property Implementation [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]StorageDevice VersionString Enclosure firmware string HPSA_EnclosureFirmware 15-2-16 SMX_SAPrimordialPool Class The SMX_SAPrimordialPool class implements the HPSA_PrimordialPool class and represents the total raw storage managed by the array controller. There is one instance per array system. The following table lists the properties implemented.
Property Name Property Implementation the total space on all drives connected to this controller. HPSA_PrimordialPool 15-2-17 SMX_SAStoragePool Class The SMX_SAStoragePool class implements the HPSA_StoragePool class and represents any concrete storage pools created on an array controller. There is one instance per array system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and .
15-2-18 SMX_SAMediaAccessStatData Class The SMX_SAMediaAccessStatData class implements the HPSA_MediaAccessStatData and represents the Monitoring and Performance data counters on HP Disk Drives. The following table lists the properties implemented.
Property Name Property Implementation OtherTimeOuts See HP Smart Array Profile SCSIBusFaults See HP Smart Array Profile SectorsRead See HP Smart Array Profile SectorsWritten See HP Smart Array Profile SeekCount See HP Smart Array Profile SeekErrors See HP Smart Array Profile ServiceHours See HP Smart Array Profile SpinUpErrors See HP Smart Array Profile RetryRecoveredReadErrors See HP Smart Array Profile RetryRecoveredWriteErrors See HP Smart Array Profile 15-2-19 SMX_SAStorageSetting
Property Name ChangeableType DataRedundancyGoal DataRedundancyMax DataRedundancyMin Property Implementation 0 (Not Changeable) 1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60) 2 (RAID 1, RAID 1+0, RAID 5+1) 1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60) 2 (RAID 1, RAID 1+0, RAID 5+1) 1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60) 2 (RAID 1, RAID 1+0, RAID 5+1) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 NoSinglePointOfFailure False – RAID 0 True – RAID 1+0,
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Port ElementName Where: is the name of the port this drive cage is connected.
15-2-21 SMX_SASCSIProtocolEndpoint Class The SMX_SASCSIProtocolEndpoint class implements the HPSA_SCSIProtocolEndpoint class and represents an access point to storage resources. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and . Refer to “Physical Location” for more information.
Property Name Property Implementation 0 (Unknown) 2 (Initiator) Role 3 (Target) 4 (Both Initiator and Target) HPSA_SCSIProtocolEndpoint 15-2-22 SMX_SASCSIProtocolController Class The SMX_SASCSIProtocolController class implements the HPSA_SCSIProtocolController class and represents a view a SCSI resources on the array controller. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and .
Property Name RequestedState Property Implementation 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASCSIProtocolController DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name TypeOfSet[0] Property Implementation 4 (Sparing) HPSA_RedundancySet 15-2-24 SMX_SAStorageRedundancySet Class The SMX_SAStorageRedundancySet class implements the HPSA_StorageRedundancySet class and represents disk sparing aspect of a RAID configuration. There is an instance for every logical drive that has spare drives configured. The following table lists the properties implemented.
15-2-25 SMX_SAStorageSpecificCollection Class The SMX_SAStorageSpecificCollection class implements the HPSA_StorageSpecificCollection class and represents a collection of smart array controllers that have been grouped together to report consolidated status. The following table lists the properties implemented.
Property Name Property Implementation Description Drive Cage ElementName Drive Cage CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Duplex Top, Duplex Bottom, Non Duplex ElementLocationTagDesc 22 (Drive Cage) HBA Port identifier LocationInformation[0] For example: J3 For example: 2I For example: 1E LocationInfoDesc[0] Port HPSA_DriveCageLocation 15-2-27 SMX_SAArraySystemLocation Class The SMX_SAArraySystemLocation class implements the HPSA_ArraySys
Property Name Property Implementation Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag PCI Slot Number – when ‘Adapter’ is specified in ElementLocationTagDesc ElementLocationTagDesc 23 (Adapter) – for internal HBA’s Array of text values representing the location components that describe this Ethernet Controller Physical location. LocationInformation[0] LocationInfoDesc[0] per LocationInfornation[0].
Property Name Property Implementation Bay: 5 CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number of Disk Drive - When ‘Bay’ is specified in ElementLocationTagDesc. ElementLocationTagDesc 20 (Bay)– when firmware supports Bay numbering HPSA_DiskDriveLocation 15-2-29 SMX_SAArrayControllerLocation Class The SMX_SAArrayControllerLocation class implements the HPSA_ArrayControllerLocation class and represents a location string for the array controller.
Property Name Property Implementation For Internal HBA’s: PCI Slot Number ElementLocationTag For example: 3 – for adapter in PCI Slot 3 For example: 0 – for Embedded adapter ElementLocationTagDesc 23 (Adapter) – for Internal HBA’s Array of text values representing the location components that describe this Ethernet Controller Physical location. LocationInformation[0] LocationInfoDesc[0] per LocationInfornation[0].
Property Name Property Implementation For Primodial Pools: Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal ElementName For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation 0 (When number of drives <= 1) PackageRedundancyDefault 1 (When number of drives = 2 or 3) 2 (When number of drives > 3) 0 (When number of drives <= 1) PackageRedundancyMax 1 (When number of drives = 2 or 3) 2 (When number of drives > 3) PackageRedundancyMin 0 HPSA_StorageCapabilities 15-2-31 SMX_SAProduct Class The SMX_SAProduct class implements the HPSA_Product class and represents the top level marketing information for the array system.
15-2-32 SMX_SAStorageEnclosureLocation Class The SMX_SAStorageEnclosureLocation class implements the HPSA_StorageEnclosureLocation class and represents a location string for the enclosure. The following table lists the properties implemented. Property Name Property Implementation Enclosure location ElementName Port: Box: Where: is the port and is the box number. Enclosure location Port: Box: Caption Where: is the port and is the box number.
15-2-34 SMX_SAStorageVolumeStorageSetting (Association) The following table lists the associations implemented for this class. Property Name Property Implementation ManagedElement SMX_SAStorageVolume SettingData SMX_SAStorageSetting IsCurrent 1 (Set to Is Current) IsDefault 1 (Set to Is Default) 15-2-35 SMX_SAPrimordialPoolStorageCapabilities (Association) The following table lists the associations implemented for this class.
SMX_SAArraySystemSCSIProtocolController (Association) 15-2-38 The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SASCSIProtocolController 15-2-39 SMX_SAArraySystemPortController (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAStorageExtent 15-2-43 SMX_SAArraySystemSPIPort (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SASPIPort 15-2-44 SMX_SAArraySystemDAPort (Association) The following table lists the associations implemented for this class.
15-2-47 SMX_SAComputerSystemArraySystem (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent HP_ComputerSystem PartComponent SMX_SAArraySystem 15-2-48 SMX_SAArraySystemArrayController (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation GroupComponent SMX_SAStorageEnclosure PartComponent SMX_SADriveCage SMX_SAPhysicalPackageArrayControllerPhysicalPackag e (Association) 15-2-52 The following table lists the associations implemented for this class.
GroupComponent SMX_SADriveCage PartComponent SMX_SADiskPhysicalPackage 15-2-56 SMX_SAStoragePoolStorageExtent (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAStoragePool PartComponent SMX_SAStorageExtent 15-2-57 SMX_SAPrimordialPoolStorageExtent (Association) The following table lists the associations implemented for this class.
SMX_SAStorageRedundancySetStorageExtent (Association) 15-2-60 The following table lists the associations implemented for this class. Property Name Property Implementation Collection SMX_SAStorageRedundancySet Member SMX_SAStorageExtent 15-2-61 SMX_SAArraySystemFirmware (Association) The following table lists the associations implemented for this class.
ElementSoftwareStatus[0]: ElementSoftwareStatus 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_SAStorageEnclosureProcessorEnclosureFirmware (Association) 15-2-64 The following table lists the associations implemented for this class.
Antecedent SMX_SADiskDrive Dependent SMX_SAStorageExtent 15-2-67 SMX_SADiskPhysicalPackageDiskDrive (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SADiskPhysicalPackage Dependent SMX_SADiskDrive 15-2-68 SMX_SAStoragePoolStorageVolume (Association) The following table lists the associations implemented for this class.
Dependent SMX_SAStorageExtent SMX_SASpareExtentStorageRedundancySet (Association) 15-2-71 The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageRedundancySet 15-2-72 SMX_SAStorageExtentStorageVolume (Association) The following table lists the associations implemented for this class.
15-2-75 SMX_SAStorageGroupHostedCollection (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent HP_ComputerSystem Dependent SMX_SAStorageSpecificCollection 15-2-76 SMX_SAPhysicalPackageArraySystem (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation Element SMX_SAArrayControllerPhysicalPackage PhysicalLocation SMX_SAArrayControllerLocation SMX_SAPhysicalPackageArraySystemLocation (Association) 15-2-80 The following table lists the associations implemented for this class.
Property Name Property Implementation AvailableSAP SMX_SASCSIProtocolEndpoint ManagedElement SMX_SASCSIProtocolController SMX_SAStorageEnclosureEnclosureLocation (Association) 15-2-84 The following table lists the associations implemented for this class.
Property Name Property Implementation CIM_ServiceAccessPoint SystemCreationClassName SMX ArraySystem SystemName The property value of HP_ArraySystem.
Property Name Property Implementation CIM_ManagedSystemElement The same value as the DeviceID property of the instance of SMX_ISASPort associated to this instance through the association SMX_ISASPortISASSCSIPE. Name CIM_ServiceAccessPoint SystemCreationClassName SMX ArraySystem SystemName The property value of HPSA_ArraySystem.
Property Name Property Implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName SMX ArraySystem SystemName The property value of HP_ArraySystem.name CreationClassName SMX_TSASPort DeviceID The same value as the SMX_TSASSCSIProtocolEndpoint.Name property of the instance associated through SMX_ISASPortISASSCSIPE.
Property Name Property Implementation 2 (OK) OperationalStatus For multi-path supported firmware implementations, the status of the port is OK, and the status of the path is the only thing that can be detected. CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName SMX ArraySystem SystemName The property value of HP_ArraySystem.name CreationClassName SMX_ISASPort SMX PortController.
Dependent SMX_ISASSCSIProtocolEndpoint SMX_ArraySystemISASSCSIProtocolEndPoint (Association) 15-2-90 The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_ArraySystem Dependent SMX_ISASSCSIProtocolEndpoint 15-2-91 SMX_ArraySystemISASPort (Association) The following table lists the associations implemented for this class.
15-2-94 SMX_TSASPortTSASSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_TSASPort Dependent SMX_TSASSCSIProtocolEndpoint 15-2-95 SMX_ArraySystemTSASPort (Association) The following table lists the associations implemented for this class.
15-3-1 OK HP_DeviceIndication: Physical Drive Status Changed to Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed from a nonOK state to OK.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name HWSerialNumber Property Implementation Physical Disk Serial Number HP_DeviceIndication DeviceModel Physical Disk Model string Controller Location DeviceControllerLogicalLocation For example: SmartArray 642 in Slot 2 FailureDescription VariableNames[] DriveInterface LastFailureDescription VariableTypes[] String (1) uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 202 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions Check for failed or removed physical drives.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_DeviceIndication DeviceModel Physical Disk Model string Controller Location DeviceControllerLogicalLocation For example: SmartArray 642 in Slot 2 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING 15-3-3 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A physical dri
Property Name Property Implementation Summary Physical drive is now rebuilding. EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Physical Drive Status Changed to Rebuilding NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name SystemVirtualUUID Property Implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string Physical Disk Location string HWLogicalLocation For example: Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number FailureDescription VariableNames[] DriveInterface LastFailureDescripti
Property Name Property Implementation PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other system
Property Name VariableTypes[] Property Implementation String (1) uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name Property Implementation RecommendedActions No action is recommended.
Property Name Property Implementation RackName * Rack name, if one exists RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication Logical drive number and RAID Level HWLogicalLocation For example: LogicalDrive1 (RAID 1+0).
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR 15-3-6 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed to Error.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name VariableValues[] Property Implementation FailureDescription short description of the failure HP_DeviceIndication SMX_SAStorageVolumeIndication Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus DeviceOperationalStatus[1]: SMX_SAStorageVolume.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 103 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of physical drives. Degraded status may be caused by failed or missing physical drives, or a data recovery operation on one or more physical drives.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation Previous OperationStatus values for Storage Volume DeviceOperationalStatusPrevious[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatusPrevious DeviceOperationalStatusPrevious[1]: SMX_SAStorageVolume.
Property Name Property Implementation EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Array Controller Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string Array Controller Location string HWLogicalLocation For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA
Property Name Property Implementation AlertingManagedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions Check controller status and run diagnostics.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Redundancy state has been set to Active 15-3-10 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller redundancy state has changed from Standby to Active.
Property Name Property Implementation ProbableCauseDescription Array Controller Redundancy State Changed to Active NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation Array Controller Location string HWLogicalLocation For example: Smart Array P600 in Slot 5 HWManufacturer SAEnclosureFirmware HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 4 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of the partner array controller.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Redundancy has been restored 15-3-12 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description Controller has detected that Redundancy has been restored and can communicate with partner controller.
Property Name Property Implementation ProbableCauseDescription Array Controller Redundancy has been Restored NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation Array Controller Location string HWLogicalLocation For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 6 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Battery Status Changed to not fully charged 15-3-14 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Battery status has changed to Not Fully Charged.
Property Name Property Implementation ProbableCauseDescription Controller Battery Status Changed to Not Fully Charged NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation Array Controller Location string HWLogicalLocation For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 8 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check battery connection and replace if necessary.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_DeviceIndication DeviceModel 15-3-16 Array Controller Model string HP_DeviceIndication: Controller Cache Status - OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Cache status has changed from non-OK to OK.
Property Name Property Implementation NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemGUID Platform GUID of the computer system generating the indication FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA
Property Name Property Implementation AlertType 5 (Device Alert) EventID 10 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Cache Status Permanently Disabled 15-3-18 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Cache status has changed to Permanently Disabled.
Property Name Property Implementation ProbableCause 35 (Performance Degraded) ProbableCauseDescription Array Controller Cache Status Changed to Permanently Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string Array Controller Location string HWLogicalLocation For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA
Property Name Property Implementation AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 301 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to Fully Redundant. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 302 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
Property Name Property Implementation PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to Degraded Redundancy.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other system
HP_DeviceIndication: Enclosure Temperature sensor Status changed to OK 15-3-22 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed from non-OK to OK.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name DeviceModel Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Warning 15-3-23 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition.
Property Name Property Implementation ProbableCause 51 (Temperature Unacceptable) ProbableCauseDescription Temperature Status Changed to Warning Condition NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation Enclosure Location string HWLogicalLocation For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Critical 15-3-24 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Des
Property Name SystemCreationClassName Property Implementation CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Critical EventCategory 24 (Primary Storage Cooling) ProbableCause 51 (Temperature Unacceptable ) ProbableCauseDescription Temperature Status Changed to Critical NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
Property Name Property Implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication Enclosure Location string HWLogicalLocation For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel 15-3-25 OK Enclosure Model string
Property Name Property Implementation RecommendedActions No action is recommended.
Property Name Property Implementation RackName * Rack name, if one exists RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication Enclosure Location string HWLogicalLocation For example: Port 1I Box 1 HWSerialNumber Enclo
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 306 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Property Name SystemGUID Property Implementation Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_DeviceIndication Enclosure Model string DeviceModel 15-4 Physical Location The Physical Location is a string representing the Smart Array device phy
16 HP Insight Manager WBEM System Fan Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) System Fan provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
16-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
16-2-1 SMX_Fan Class The SMX_Fan class is used to model fans on servers. Fan numbers for existing instances do not change when other fans are added and removed. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this fan from the name displayed by the MP or iLO and the location. For example: Fan 1 at CabinetFan=01 Description of this fan, including ElementName, FanType and StatusDescription[0].
Property Name Property Implementation the location. For example: Fan 1 at CabinetFan=01 CIM_LogicalDevice CreationClassName SMX_Fan DeviceID Unique identifier for this fan instance. SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SMX_ComputerSystem.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Cooling Collection This is a collection of all devices including fans that provide cooling. GroupStatusDescription Description ElementName Where: GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property. Cooling Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this cooling collection instance.
16-2-3 SMX_FanRedundancySet Class The SMX_FanRedundancySet class is used to model fan redundancy sets on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this redundancy set, for example: Cooling Redundancy Set Where: represents the number of the redundancy set instance.
Property Name Property Implementation redundancy set to provide cooling. 16-2-4 SMX_MemberOfFanRedundancy Class The SMX_MemberOfFanRedundancy class is used to represent an association between the HP_Fan and HP_FanRedundancySet classes. The following table lists the properties implemented.
16-2-7 SMX_HostedFanCollection Class The SMX_HostedFanCollection class is used to represent an association between HP_FanCollection and the computer system that contains this collection. The following table lists the properties implemented.
Property Name Property Implementation position CabinetFan=01 printed on the system. ElementName User displayable name of this fan location, including the name displayed by the MP or iLO. For example on HP ProLiant: Fan 1 at CabinetFan=01 CIM_Location Name Unique identifier for this fan location instance. PhysicalPosition Opaque identifier for the physical position of this fan HP_Location Location string based on ElementLocationTagDesc.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this fan from the name displayed by the MP or iLO and location. For example: Fan 1 at CabinetFan=01 Description of this fan module, including ElementName, type and status. For example: provides cooling for FanType.
Property Name Property Implementation Unique identifier for this fan instance. Tag CIM_PhysicalPackage 0 (Unknown) RemovalConditions 3 (Removable when off) 4 (Removable when on or off) PackageType 16-2-12 7 (Fan) SMX_SystemPhysicalFan Class The SMX_SystemPhysicalFan class implements the HP_SystemPhysicalFan class and association the HP_ComputerSystemChassis instance with HP_FanModule. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Short description of this fan slot, to include the number and location. Caption For example: Fan 1 at CabinetFan=01 Description of the fan slot. Description For example: Fan 1 at CabinetFan=01 Name of the fan slot.
Property Name Property Implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_FanSlot 16-2-16 SMX_FanInSlot Class The SMX_FanInSlot class implements the HP_FanInSlot class and associates the HP_FanSlot instance with HP_FanModule instances. The following table lists the properties implemented.
Property Name Property Implementation StatusDescriptions[0] Fan speed sensor is operating properly—if OperationalStatus[0] is 2 (OK) HealthState 5 (OK) – if fan sensor is operating properly Name Name of fan speed sensor from the name displayed by the MP or iLO and the location. For example: Fan speed sensor for Fan 1 at CabinetFan=01 CIM_LogicalDevice CreationClassName SMX_FanSpeedSensor DeviceID Unique identifier for fan slot. SystemCreationClassName HP_ComputerSystem.
16-2-18 SMX_SystemFanSensor SMX_SystemFanSensor is used to represent an association between SMX_FanSensor and the computer system that contains this fan sensor. Property Name Property Implementation GroupComponent References HP_ComputerSystem PartComponent References SMX_FanSensor 16-2-19 SMX_AssociatedFanSensor SMX_AssociatedFanSensor is used to represent an association between HP_Fan and the SMX_FanSpeedSensor that is reporting the speed of the fan.
Property Name Property Implementation HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses For example: 01.05.00 Contains a list of all the IP addresses of the computer system generating the indication. On ESX, 39 (VM) OSType On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: major.minor.
Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fan has been removed Where: is the fan number that was removed. AlertingManagedElement WBEM Path of the SMX_Fan instance. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 ProviderName HP Cooling RecommendedActions Check the fan configuration and ensure that this fan was removed intentionally.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 2 ProviderName HP Cooling RecommendedActions No action is recommended. HP_AlertIndication Summary Fan inserted EventCategory 23 (System Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan inserted 16-3-4 HP_DeviceIndication: Fan Failed Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A fan has failed.
Property Name ProbableCause Property Implementation 94 (Fan Failure) ProbableCauseDescription Fan Failed 16-3-5 HP_DeviceIndication: Fan Repaired Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fan has been repaired. The fan is now operating properly. Description Where: is the SMX_Fan.Caption for the fan that has been repaired. AlertingManagedElement WBEM Path of SMX_Fan instance representing the failed fan.
Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication A fan has degraded. Description Where: is the SMX_Fan.Caption for the fan that has degraded. AlertingManagedElement WBEM Path of SMX_Fan instance representing the degraded fan. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 9 ProviderName HP Cooling RecommendedActions Check the degraded fan and replace if necessary.
Property Name Property Implementation redundancy set with reduced redundancy. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 5 ProviderName HP Cooling RecommendedActions No action is recommended.
Property Name Property Implementation HP_AlertIndication Summary Cooling redundancy lost EventCategory 23 (System Cooling) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Cooling Redundancy has been Lost 16-3-9 HP_DeviceIndication: Fan Redundancy Restored Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Cooling redundancy for the system has been restored.
16-3-10 HP_DeviceIndication: Fan Redundancy Failed Important: This indication is not supported on HP ProLiant systems because redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Cooling redundancy for the system has failed. (RedundancySetCaption) Description Where: RedundancySetCaption is SMX_FanRedundancySet.
17 HP Insight Management WBEM System Memory Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) System Memory provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Memory Profile HP WBEM TC 1.0 HP Memory Physical Asset Profile HP WBEM TC 1.0 HP Location Profile HP WBEM TC 1.
17-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation. When the Property Implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis.
Property Name Property Implementation StatusDescriptions[0]contains descriptive text per OperationalStatus[0]: StatusDescriptions OK Unknown Degraded 5 (OK), when OperationalStatus[0] = 2 (OK) HealthState 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) Name System Memory CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice Cr
Property Name Property Implementation CIM_Memory StartingAddress Beginning address of the memory in kilobytes EndingAddress Ending address of the memory in kilobytes Volatile TRUE HP_Memory SMX_Memory 17-2-2 SMX_SystemMemory Class The SMX_SystemMemory class represents an association between SMX_Memory and the computer system that contains the memory. There is one instance of this class. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Caption Physical Memory Module . Refer to “Physical Location” for more information. CIM_ManagedSystemElement Enumerator indicating the memory module operational status. OperationalStatus[0] contains overall memory module status OperationalStatus OperationalStatus[1] contains detailed memory module status (as needed) For details, see “Properties for Memory Module Status”.
Property Name PartNumber SerialNumber Property Implementation Part number of the memory module. This property is conditional; it is populated if the data is available. Manufacturer allocated serial number of the memory module. This property is conditional; it is populated if the data is available.
Property Name Property Implementation String identifying the physically labeled bank where the memory is located. BankLabel For examples: 'DIMM 0A' or 'PROC 1 DIMM 0A' or 'Board 1,0A' This property is conditional; it is populated if the data is available. SMX_MemoryModule An array that contains raw Serial Presence Detect information for the memory module. Each array element contains a byte of the Spd. Spd This property is conditional; it is populated if the data is available.
Property Name Property Implementation CIM_ManagedElement Caption Physical Memory Module . Refer to “Physical Location” for more information. CIM_ManagedSystemElement Enumerator indicating the memory board operational status. OperationalStatus[0] contains overall memory board status OperationalStatus OperationalStatus[1] contains detailed memory board status (as needed) For details, see “Properties for Memory Board Status”.
Property Name Property Implementation Removal conditions of the memory board: When the memory board is the system board: RemovalConditions 2 (Not Applicable) When the memory board is not the system board: 3 (Removable when off) 4 (Removable when on or off) PackageType 9 (Module/Card) CIM_Card HostingBoard True – memory board is on the baseboard.
OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Condition failure warranty. Correctable error threshold for pre-failure warranty has been exceeded Memory board has a configuration 3 (Degraded) error, e.g. there is a problem with the board release latch (unlock error) or there is an improper Degraded configuration of memory modules on the board.
Property Name Property Implementation CIM_ManagedElement Caption Memory Module . Refer to “Physical Location” for more information. CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] = 2 (OK) StatusDescriptions StatusDescriptions[0] = Memory module slot status:OK HealthState 5 (OK) Name Memory Module . Refer to “Physical Location” for more information.
17-2-7 SMX_MemoryBoardSlot Class The SMX_MemoryBoardSlot class represents memory board slots on HP servers. There is an instance of this class for each memory board slot in the system (whether the slot is occupied or not). The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Memory Board Slot . Refer to “Physical Location” for more information.
Property Name Property Implementation Note: Not unique on HP Cellular servers. SMX_MemoryBoardSlot 17-2-8 SMX_MemoryModuleInSlot Class The SMX_MemoryModuleInSlot class represents the association between an SMX_MemoryModule and the SMX_MemoryModuleSlot where it resides. The following table lists the properties implemented.
17-2-10 SMX_MemoryModuleSlotOnBoard Class The SMX_MemoryModuleSlotOnBoard class represents an association between a SMX_MemoryModuleSlot and the SMX_MemoryBoard that contains it. The following table lists the properties implemented.
Property Name Property Implementation Opaque key. PhysicalPosition Example for memory socket number 2 on cpu, board, or cartridge number 1: FF-FF-FF-FF-01-02-FF-79 HP_Location Opaque key. ElementLocationTag Example for memory socket number 2 on cpu, board, or cartridge number 1: FF-FF-FF-FF-01-02-FF-79 ElementLocationTagDesc 8 (Memory Module) Indexed array: LocationInformation[0] per LocationInformation[0].
Property Name Caption Description ElementName Property Implementation Memory Board Slot Location . Refer to “Physical Location” for more information. Memory Board Slot Location . Refer to “Physical Location” for more information. Memory Board Slot Location . Refer to “Physical Location” for more information. CIM_Location Name Opaque key of the form: HPQ:SMX_MemoryBoardSlotLocation: . Opaque key.
17-2-13 SMX_MemoryModuleSlotElementLocation Class The SMX_MemoryModuleSlotElementLocation class extends the CIM_ElementLocation class and is used to associate a memory module slot (SMX_MemoryModuleSlot) with its corresponding location (SMX_MemoryModuleSlotLocation). There is an instance of this class for each memory module slot in the system (whether the slot is occupied or not). The following table lists the properties implemented.
17-2-15 SMX_SystemMemoryModule Class The SMX_SystemMemoryModule class represents an association between SMX_MemoryModule and SMX_ComputerSystemChassis. There is an instance of this class for each memory module slot on the chassis system board (whether the slot is occupied or not). Only system board resident memory module slots are instantiated. The following table lists the properties implemented.
17-2-17 SMX_MemoryRedundancySet Class The SMX_MemoryRedundancySet class represents memory board redundancy on HP servers supporting Advanced Memory Protection (AMP). There is one instance of this class on systems supporting AMP. This class is not instantiated on non-AMP systems. The following table lists the properties implemented.
Property Name Property Implementation Represents the current memory redundancy status as follows: 2 (Fully Redundant) System is operating properly in the Advanced Memory Protection mode given in the TargetConfiguration property. 3 (Degraded Redundancy) RedundancyStatus Degraded Redundancy can occur in either of the following conditions: • System is not operating in the TargetConfiguration mode (the CurrentConfiguration mode does not match the TargetConfiguration mode).
Property Name Property Implementation The desired or targeted mode of the Advanced Memory Protection system.
Property Name Property Implementation Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the ‘worst-of’ algorithm for physical memory boards and memory modules.
- 0 (Unknown) 2 (OK) 0 (Unknown) - 0 (Unknown) 3 (Degraded) 3 (Degraded) - 0 (Unknown) 0 (Unknown) 0 (Unknown) 17-2-19 SMX_HostedMemoryCollection Class The SMX_HostedMemoryCollection class represents an association between SMX_MemoryCollection and the computer system that contains this collection. The following table lists the properties implemented.
Property Name References CIM_PhysicalElement Member 17-2-21 Property Implementation (either SMX_MemoryModule or SMX_MemoryBoard) SMX_MemberOfMemoryRedundancySet Class The SMX_MemberOfMemoryRedundancySet class represents an association between SMX_MemoryBoard and SMX_MemoryRedundancySet. The following table lists the properties implemented.
17-2-23 SMX_SystemMemoryModuleSlot Class The SMX_SystemMemoryModuleSlot class represents an association between SMX_MemoryModuleSlot and SMX_ComputerSystemChassis. There is an instance of this class for each memory module slot on the chassis system board (whether the slot is occupied or not). Only system board resident memory module slots are instantiated. The following table lists the properties implemented.
17-3 Provider Indications Indications Generated by the Provider 17-3-1 Generates WBEM indications described in the following sections.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemVirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. SystemVirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. EnclosureName HP_BladeEnclosureCS.
Property Name Property Implementation Summary Memory module has failed or is predicted to fail EventCategory 3 (Memory) ProbableCause 1 (Other) ProbableCauseDescription Memory Module Failed or Predicted to Fail 17-3-3 SMX_MemoryIndication: Memory Board Error Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A memory board has an error. (MemoryBoardCaption) Description Where: MemoryBoardCaption is the SMX_MemoryBoard.
SMX_MemoryIndication: Memory Redundancy Degraded 17-3-4 Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The AMP system is operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail. (TargetConfiguration/CurrentConfiguration) Where: TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration.
Property Name PerceivedSeverity Property Implementation 2 (Information) CIM_AlertIndication Description The AMP system is operating normally in the targeted configuration. If redundancy was previously degraded, redundancy has been restored. (TargetConfiguration) Where: TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration. AlertingManagedElement WBEM Path of SMX_MemoryRedundancySet instance representing the Memory Redundancy.
HP Integrity Cellular Servers All Systems Socket= Cabinet= MemoryBoard= Cell= ProcessorBoard= - System Mainboard (referring to System Board/motherboard) - HP BladeServers in C3000 / C7000 Enclosures Blade= - HP Insight Management WBEM System Memory Provider 424