HP Insight Management WBEM Providers 2.70 for Windows Server 2003/2008 Event Log Messages Reference Guide

Table 7-1 Insight Provider Indications for Version 2.7.0.0 (continued)
Windows Event
ID (short)
Windows Event
ID (full)
Windows Event
SourceDescriptionSummaryEvent IDProvider Name
112147483659HP Smart
Array
A Smart Array
controller
Cache status
has changed to
Permanently
Disabled. The
controller has
detected a
problem with
the cache and
has disabled the
cache
permanently.
Array
controller
cache status
permanently
disabled
11HP Smart
Array
122147483660HP Smart
Array
A Smart Array
controller
Cache status
has changed to
not configured.
This may be
caused by a
configuration
change.
Array
controller
cache status
not configured
12HP Smart
Array
1011073741925HP Smart
Array
A logical drive
status has
changed from a
non-OK state to
OK.
Logical drive
status OK
101HP Smart
Array
1023221225574HP Smart
Array
A logical drive
status has
changed to
Error.
Logical drive
status error
102HP Smart
Array
1032147483751HP Smart
Array
A logical drive
is in a degraded
state. Device is
still servicing
I/O but
redundancy
may be
degraded or
lost.
Logical drive
in degraded
state
103HP Smart
Array
1042147483752HP Smart
Array
A logical drive
is in a degraded
state. Multipath
support is Lost.
Either cable is
removed or not
configured.
Logical drive
in degraded
state -
multipath
failure
104HP Smart
Array
2011073742025HP Smart
Array
A physical
drive status has
changed from a
non-OK state to
OK.
Physical Drive
status OK
201HP Smart
Array
2023221225674HP Smart
Array
A physical
drive status has
changed to
Error.
Physical drive
status Error
202HP Smart
Array
33