HP Insight Management WBEM Providers 2.70 for Windows Server 2003/2008 Event Log Messages Reference Guide

Table 7-1 Insight Provider Indications for Version 2.7.0.0 (continued)
Windows Event
ID (short)
Windows Event
ID (full)
Windows Event
SourceDescriptionSummaryEvent IDProvider Name
3082147483956HP SCSIA Storage
Enclosure
Temperature
sensor Status
changed to
Warning
Condition. This
indicates the
enclosure
temperature is
above normal,
otherwise
enclosure is still
operating
normally.
Temperature
sensor status
Warning
Condition
308HP SCSI
3093221225781HP SCSIA Storage
Enclosure
Temperature
sensor status
has changed to
Critical. An
enclosure
temperature is
reaching the
maximum
allowed
temperature for
normal
operation. A
shutdown is
imminent.
Action is
required before
loss of data
occurs.
Temperature
sensor status
Critical
309HP SCSI
11073741825HP Smart
Array
A Smart Array
controller status
has changed
from non-OK to
OK.
Controller
status OK
1HP Smart
Array
23221225474HP Smart
Array
A Smart Array
controller status
has changed to
Error.
Controller
status Error
2HP Smart
Array
32147483651HP Smart
Array
A Smart Array
controller
redundancy
state has
changed from
Standby to
Active.
Controller
redundancy
state set to
Active
3HP Smart
Array
31