HP Insight Management WBEM Providers 2.70 for Windows Server 2003/2008 Event Log Messages Reference Guide
Table 7-1 Insight Provider Indications for Version 2.7.0.0 (continued)
Windows Event
ID (short)
Windows Event
ID (full)
Windows Event
SourceDescriptionSummaryEvent IDProvider Name
10051073742829HP SensorA fault tolerant
power supply is
no longer
providing
power for a
power
redundancy set.
(%s)
Power
redundancy
reduced
5HP Power
10062147484654HP SensorPower
redundancy has
been lost. (%s)
Power
redundancy
lost
6HP Power
10071073742831HP SensorA fault tolerant
power supply
has been added
to a power
redundancy set.
(%s)
Power
redundancy
gained
7HP Power
10081073742832HP SensorPower
redundancy for
the system has
been restored.
(%s)
Power
redundancy
restored
8HP Power
10093221226481HP SensorA power supply
has failed input
power lost. (%s)
Power supply
failed - input
power lost
9HP Power
12147483649HP ProcessorA processor has
failed.
Processor
failed
1HP Processor
22147483650HP ProcessorA processor has
been disabled
by ROM Based
Setup (RBSU).
Processor
deconfigured
2HP Processor
13221225473HP SystemThe system has
rebooted from
Automatic
Server Recovery
(ASR) event.
ASR reboot
occurred
1HP Recovery
23221225474HP SystemThe system has
rebooted from a
thermal
shutdown
event.
Thermal
reboot
occurred
2HP Recovery
11073741825HP SASAn SAS/SATA
HBA status has
changed from
non-OK to OK.
HBA status
OK
1HP SAS
23221225474HP SASAn SAS/SATA
HBA status has
changed to
Error.
HBA status
Error
2HP SAS
1011073741925HP SASA logical drive
status has
changed from
non-OK to OK.
Logical Drive
status OK
101HP SAS
25