HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
4-4-8 Power Supply Redundancy Restored
Table 4-31 HP_SensorHardwareIndication: Power Supply Redundancy Restored
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description Power redundancy for the system has been restored.
(RedundancySetCaption), where RedundancySetCaption
is HP_WinPowerRedundancySet.Caption of the
redundancy set the power redundancy set with restored
redundancy
AlertingManagedElement WBEM Path of HP_WinPowerRedundancySet instance
representing the power redundancy set with restored
redundancy
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 8
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Power
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power redundancy restored
EventCategory 16 (System Power)
ProbableCause 1 (Other)
ProbableCauseDescription Power Redundancy has been Restored
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication