HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 4-29 HP_SensorHardwareIndication: Power Supply Redundancy Lost
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-7 Power Supply Redundancy Gained
Table 4-30 HP_SensorHardwareIndication: Power Supply Redundancy Gained
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fault tolerant power supply has been added to a
power redundancy set. (RedundancySetCaption), where
RedundancySetCaption is HP_WinPowerRedundancySet.
Caption of the redundancy set with an added power
supply
AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet
instance representing the redundancy set with an
added power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 7
ProviderName HP Power
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power redundancy gained
EventCategory 16 (System Power)
ProbableCause 1 (Other)
ProbableCauseDescription Power Redundancy has been Gained