HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 4-27 HP_SensorHardwareIndication: Power Supply Repaired
Property name Property implementation
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-5 Power Supply Redundancy Reduced
Table 4-28 HP_SensorHardwareIndication: Power Supply Redundancy Reduced
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fault tolerant power supply is no longer providing
power for a power redundancy set.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinPowerRedundancySet.Caption
for the redundancy set with reduced redundancy.
AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet
instance representing the redundancy set with reduced
redundancy.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 5
ProviderName HP Power
RecommendedActions No action is recommended.