HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 23-34 HP_SATADeviceIndication: Disk Drive status Degraded
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HP_DeviceIndication
DeviceModel Physical Disk Model string
23-4-6 Physical Drive Status Changed to Predictive Failure
Table 23-35 HP_SATADeviceIndication: Disk Drive status Predictive Failure
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded/Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Disk Drive status has changed to Predictive Failure.
AlertingManagedElement WBEM path of the HP_SATADiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 605
ProviderName HP SATA
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Predictive Failure.
EventCategory 6 (Primary Storage Device)
ProbableCause 1 (Other)