HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 21-35 HP_TapeDriveDeviceIndication: Offline Drive Now Missing
Property name Property implementation
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
HP_HardwareIndication
HWFirmwareVersion Enclosure F/W version string (It must match the
HP_TapeDriveFirmware.VersionString)
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number (It must match the
HP_StorageEnclosure.SerialNumber)
HP_DeviceIndication
DeviceModel Enclosure Model string
HP_TapeDriveDeviceIndication
21-4-10 Degraded Drive Now Missing
Table 21-36 HP_TapeDriveDeviceIndication: Degraded Drive Now Missing
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 510 (Degraded drive now missing)