HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 18-37 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to OK
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
BladeBay HP_BladeCSLocation.LocationInformation[0]
BladeName HP_ComputerSystem.Name
EnclosureName HP_BladeEnclosureCS.Name
ImpactedDomain
• 3 (Enclosure) for c-Class BladeSystems
• 4 (System) for all other systems
RackName Rack name, if one exists
RackUID Rack Unique Identifier, if one exists
HWFirmwareVersion Controller F/W version string
HWSerialNumber Controller Serial Number
HWManufacturer Name of Hardware Manufacturer
DevicePermanentNameFormat PortWWN
DevicePermanentName PortWWN
18-4-2 Fibre Channel Port status changed to Link Down
Table 18-38 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A fibre channel HBA port has changed to a state of
link down
AlertingManagedElement WBEM Path of HPFCHBA_DeviceIndication
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 6
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Fibre Channel