HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 18-35 Class: HPFCHBA_Location
Property name Property implementation
HP_Location
ElementLocationTag slot number
ElementLocationTagDesc 1 (slot)
18-3-35 HPFCHBA_PhysicalElementLocation
HPFCHBA_PhysicalElementLocation is used to represent an association between the
HPFCHBA_PhysicalPackage and HPFCHBA_Location.
Table 18-36 Class: HPFCHBA_PhysicalElementLocation
Property name Property implementation
CIM_ElementLocation
HPFCHBA_PhysicalElementLocation
Element ref:HPFCHBA_PhysicalPackage
PhysicalLocation ref:HPFCHBA_Location
18-4 Supported indications
18-4-1 Fibre Channel Port status changed to OK
Table 18-37 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (information)
IndicationTime Time of indication
CIM_AlertIndication
Description This fibre channel HBA port has returned to a status of
OK
AlertingManagedElement WBEM Path of HPFCHBA_DeviceIndication
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)