HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 17-80 HPSCSI_DeviceIndication: Fan status change—Degraded
Property name Property implementation
HWFirmwareVersion Enclosure firmware version string
HWLogicalLocation Enclosure Location string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17-4-20 Fan Status change - ERROR
Table 17-81 HPSCSI_DeviceIndication: Fan status change - ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has failed and there are not enough fans in the
fan subsystem to keep the enclosure cool.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 16
ProviderName HP SCSI
RecommendedActions Check your fan subsystem as soon as possible.
Continued operation can cause failure of the drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage enclosure fan is failed
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan Failure)
ProbableCauseDescription Fan Failure