HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-79 HPSCSI_DeviceIndication: Fan status change—OK
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Enclosure firmware version string
HWLogicalLocation Enclosure Location string
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17-4-19 Fan Status change - Degraded
Table 17-80 HPSCSI_DeviceIndication: Fan status change—Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description This SCSI Storage enclosure fan is degraded
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 18
ProviderName HP SCSI
RecommendedActions Replace fan subsystem
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary A fan has failed but there are still enough fans in the
fan subsystem to keep the enclosure cool.