HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-72 HPSCSI_DeviceIndication: Controller status ERROR
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
17-4-12 Power Supply status NOT REDUNDANT
Table 17-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description This SCSI Storage enclosure power supply was
redundant but due to a failure is not longer redundant
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 22
ProviderName HP SCSI
RecommendedActions Replace failed or missing power supply module
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication