HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-69 HPSCSI_DeviceIndication: Physical Drive status—Missing was OFFLINE
Property name Property implementation
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
17-4-9 Controller Status change—Unknown
Table 17-70 HPSCSI_DeviceIndication: Controller status changed to Unknown
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 0 (unknown)
IndicationTime Time of indication
CIM_AlertIndication
Description Controller The SCSI device has changed to a status of
Unknown
AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class
instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)