HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-64 HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure
Property name Property implementation
CIM_AlertIndication
Description SCSI physical drive status is now set to predictive
failure.
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 11
ProviderName HP SCSI
RecommendedActions Schedule replacement before actual failure occurs to
avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI physical drive predictive failure.
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription SCSI Physical Drive Predictive Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
• For Windows 2003 32-bit: 69
• For Windows 2003 64-bit: 70
• For Windows 2008 32-bit: 76
• For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication