HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 17-10 Class: HPSCSI_StorageEnclosureProcessor (CIM_ComputerSystem)
Property name Property implementation
OperationalStatus Operational status for enclosure and associated power
supplies, fans and sensors.
The use of OperationalStatus is described in the HP
Storage Enclosure Profile. Index values are populated
as follows:
OperationalStatus[0]—Enclosure status
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
OperationalStatus [1]—Fan status (See Profile)
OperationalStatus [2]—Power Supply status (See
Profile)
OperationalStatus [3]—Temp Sensor Status (See
Profile)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not applicable)
RequestedState 12 (Not applicable)
CIM_System
CreationClassName HPSCSI_StorageEnclosureProcessor
IdentifyingDescriptions Other Vendor Specific Name
NameFormat Other
CIM_ComputerSystem
Dedicated[0] 2 (Other)
OtherDedicatedDescriptions[0] SDE—Indicates Storage Device Enclosure
17-3-10 HPSCSI_HBAPortController
HPSCSI_HBAPortController represents the HBA in the host system. There is one instance per HBA.
Table 17-11 Class: HPSCSI_HBAPortController (CIM_PortController)
Property name Property implementation
CIM_ManagedElement
ElementName Controller name and location (for example, SCSI
Controller Port 1 in Slot 4)