Table 16-74 HPSAS_DeviceIndication: Physical Drive status OK
Property name Property implementation
DeviceModel Disk Model string
16-4-4 Physical Drive status ERROR
Table 16-75 HPSAS_DeviceIndication: Physical Drive status ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Error.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 202
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Error
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Physical Drive Status Changed to Error
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication