HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 16-24 Class: HPSAS_Product (CIM_Product)
Property name Property implementation
HPSAS_Product
16-3-24 HPSAS_DriveCage
HPSAS_DriveCage represents the drive cage assembly and backplane within a storage enclosure.
There can be multiple instances within a duplexed enclosure.
Table 16-25 Class: HPSAS_DriveCage (CIM_PhysicalPackage)
Property name Property implementation
CIM_ManagedElement
ElementName Port <m> Box <n>, where <m> is the name of the port
this drive cage is connected and <n> is the Box
Number
For example, Port IE Box 1
CIM_ManagedSystemElement
Name Serial Number of drive cage
N/A—when serial number is not available
CIM_PhysicalElement
CreationClassName HPSAS_DriveCage
Manufacturer Drive Cage Vendor string
Model Drive Cage Model string
PartNumber N/A–Not available in this implementation
Tag Opaque key
SerialNumber Enclosure Serial number
Version N/A–Not available in this implementation
CIM_PhysicalPackage
RemovalConditions 2 (Not Applicable)
HP_DriveCage
BackplaneSpeed See profile
DriveBays See profile
DuplexLocation See profile
HPSAS_DriveCage
16-3-25 HPSAS_EnclosureFirmware