HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 16-22 Class: HPSAS_DiskDriveLocation (HP_Location)
Property name Property implementation
ElementName Disk location
For example, Bay: 5
CIM_Location
Name Opaque key
PhysicalPosition Opaque key
HP_Location
ElementLocationTag Bay Number of Disk
ElementLocationTagDesc 20 (Bay)
HPSAS_DiskDriveLocation
16-3-22 HPSAS_StorageCapabilities
HPSAS_StorageCapabilities represents the possible capabilities of a Storage Pool.
Table 16-23 Class: HPSAS_StorageCapabilities (CIM_StorageCapabilities)
Property name Property implementation
CIM_ManagedElement
ElementName
• For Primodial Pools
Controller name and location, for example, HP 8
INT Port SAS/SATA HBA in Slot 3 for internal
• For Concrete Pools
Controller name and location:Array identifier, for
example, HP 8 INT Port SAS/SATA HBA in Slot 3:
Storage Pool for internal
CIM_Capabilities
InstanceID Opaque key
CIM_StorageCapabilities
DataRedundancyDefault
• 0 (When Pool is NonRAID)
• 1 (When number of drives = 1)
• 2 (When number of drives > 1) For example, Pool
can be configured for redundancy.
DataRedundancyMax
• 0 (When Pool is NonRAID)
• 1 (When number of drives = 1)
• 2 (When number of drives > 1) For example, Pool
can be configured for redundancy.
DataRedundancyMin
• 0 (When Pool is NonRAID)
• 1 (No single point of failure RAID)