HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 15-62 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor Status changed to Critical.
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51 (Temperature Unnacceptable)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
• For Windows 2003 32-bit: 69
• For Windows 2003 64-bit: 70
• For Windows 2008 32-bit: 76
• For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)
VariableValues Short description of failure
ImpactedDomain
• 3 (Enclosure) for c-Class BladeSystems
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name