HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 15-58 HPSA_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15-4-21 Enclosure Power Supply Status Changed to Redundant
Degraded
Table 15-59 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Power Supply Status changed to a status of Redundant
Degraded.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 303
ProviderName HP Smart Array
RecommendedActions Check the status of all enclosure power supplies.
Ensure that power supplies have not failed. Add or
replace power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication