HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-55 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
DeviceModel Array Controller Model string
15-4-18 Controller Cache Status - Permanently Disabled
Table 15-56 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Cache Status is set to a status of
Permanently Disabled. Controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 11
ProviderName HP Smart Array
RecommendedActions Check Cache controller error code. Run diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array Controller Cache Status is Permanently Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103