HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 15-54 HPSA_DeviceIndication: Controller Cache status changed to OK
Property name Property implementation
VariableTypes
• VariableTypes[0]: 1 (String)
• VariableTypes[1]: 5 (uint16)
• VariableTypes[2]: 1 (String)
VariableValues
• VariableValues[0]: Short Description of failure
• VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
• VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
ImpactedDomain
• 3 (Enclosure) for c-Class BladeSystems
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-17 Controller Cache Status—Temporarily Disabled
Table 15-55 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
CIM_Indication