HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-48 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-11 Controller Redundancy has been lost
Table 15-49 HPSA_DeviceIndication: Controller Redundancy has been lost
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Controller has detected that Redundancy has been lost
due to failure or loss of communication with partner
controller.