HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-43 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name Property implementation
HWLogicalLocation Logical drive number
For example, LogicalDrive 1 (RAID 1+0)
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationalStatus values for Storage Volume
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-6 Logical Drive Status Changed to ERROR
Table 15-44 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Logical Drive Status has changed to ERROR status.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 102
ProviderName HP Smart Array
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication