HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 2-14 HP_SystemHardwareIndication: ASR Reboot Occurred
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
2-4-2 Thermal Reboot Occurred
Table 2-15 HP_SystemHardwareIndication: Thermal Reboot Occurred
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description The system has rebooted from a thermal shutdown
event
AlertingElementFormat 1 (Unknown)
AlertType 5 (Device Alert)
EventID 2
ProviderName HP Recovery
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Thermal reboot occurred
EventCategory 16 (System Power)
ProbableCause 51 (Temperature Unacceptable)
ProbableCauseDescription Thermal Reboot Occurred
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>