Table 15-30 Class: HPSA_DiskDriveLocation (HP_Location)
Property name Property implementation
ElementName Controller name, Drive Type and Disk Location
For example, Smart Array E500 Physical Drive—Port:
1E Box 1 Bay: 5
CIM_Location
Name Opaque key
PhysicalPosition Opaque key
HP_Location
ElementLocationTag
• Bay Number of Disk Drive— When Bay is specified
in ElementLocationTagDesc.
• SCSI ID of Disk Drive—When SCSI ID is specified
in ElementLocationTagDesc
ElementLocationTagDesc
• 20 (Bay)—When firmware supports Bay numbering
• 21 (SCSI ID)
HPSA_DiskDriveLocation
15-3-30 HPSA_ArrayControllerLocation
HPSA_ArrayControllerLocation represents a location string for the array controller.
Table 15-31 Class: HPSA_ArrayControllerLocation (HP_Location)
Property name Property implementation
CIM_ManagedElement
Caption Controller name and location
Examples:
• Smart Array in Slot 3, for internal
• Active Controller: MSA500 in SystemCab03, for
external
Description Controller name and location
Examples:
• Smart Array in Slot 3, for internal
• Active Controller: MSA500 in SystemCab03, for
external
ElementName Controller name and location
Examples:
• Smart Array in Slot 3, for internal
• Active Controller: MSA500 in SystemCab03, for
external
CIM_Location