HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-24 Class: HPSA_SCSIProtocolController (CIM_SCSIProtocolController)
Property name Property implementation
HPSA_SCSIProtocolController
15-3-24 HPSA_RedundancySet
HPSA_RedundancySet represents controller redundancy if there is more than one controller in a
redundant configuration (for example, an MSA500 with two controllers.)
Table 15-25 Class: HPSA_RedundancySet (CIM_RedundancySet)
Property name Property implementation
CIM_ManagedElement
ElementName Storage System name and location (for example,
MSA500 in SystemCab03)
CIM_Collection
CIM_SystemSpecificCollection
InstanceID Opaque key
CIM_RedundancySet
LoadBalanceAlgorithm 2 (No Load Balancing)
RedundancyStatus
2 (Fully Redundant)
3 (Degraded redundancy)
TypeOfSet[0] 4 (Sparing)
HPSA_RedundancySet
15-3-25 HPSA_StorageRedundancySet
HPSA_StorageRedundancySet represents disk sparing aspect of a RAID configuration. There is an
instance for every raid set that has spare drives configured.
Table 15-26 Class: HPSA_StorageRedundancySet (CIM_StorageRedundancySet)
Property name Property implementation
CIM_ManagedElement
ElementName Storage Redundancy Set
CIM_Collection
CIM_SystemSpecificCollection
InstanceID Opaque key
CIM_RedundancySet