HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 15-12 Class: HPSA_StorageEnclosureProcessor (CIM_ComputerSystem)
Property name Property implementation
OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power
supplies, fans and sensors. The use of
OperationalStatus is described in the HP Storage
Enclosure Profile. Index values are populated as
follows.
• Index[0]—Enclosure status:
○ 0 (Unknown)
○ 2 (OK)
○ 3 (Degraded)
○ 6 (Error)
• Index[1]—Fan status (See Profile)
• Index[2]—Power Supply status (See Profile)
• Index[3]—Temp Sensor Status (See Profile)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_System
CreationClassName HPSA_StorageEnclosureProcessor
NameFormat Other
IdentifyingDescriptions[0] Other Vendor Specific Name
OtherIdentifyingInfo[0] Port Number:BoxNumber enclosure is attached to(for
example, 1E:1). For dual port SAS disks, both port
numbers appear.
CIM_ComputerSystem
Dedicated[0] 2 (Other)
OtherDedicatedDescriptions[0] SDE—Indicates Storage Device Enclosure
HPSA_StorageEnclosureProcessor
15-3-12 HPSA_PortController
HPSA_PortController represent the HBA in the host system. There is one instance per HBA. This class is
not implemented for external subsystems (for example, MSA500).
Table 15-13 Class: HPSA_PortController (CIM_PortController)
Property name Property implementation