HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

13-4-13 Ethernet Team Active Member Count Change
Table 13-37 HP_AlertIndication: Ethernet Team Active Member Count Change
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description The number of active adapters in an Ethernet team has
changed. This is due an Ethernet Team member
transitioning from OK to Degraded or Error. Further
information is available in the variable information of
this indication. This is an optional indication that can
be disabled through the Ethernet Event Provider
settings.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet), reporting a change in
active member count
AlertingElementFormat 2 (CIMObjectPath)
AlertType 2 (Communications Alert)
Event Id 13
ProviderName HP Ethernet
RecommendedActions[] View the Ethernet and Ethernet Team Member status in
the HP Network Configuration Utility (NCU).
View the System Event Log for additional information.
SystemCreationClassName CreationClassName of the computer system generating
the indication
SystemName Name of the computer system generating the indication
HP_AlertIndication
Summary An Ethernet Team reported a change in the number of
active members in the team
EventCategory 9 (Network Device)
EventSubCategory 12 (Ethernet Team)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication