HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 9-2 Class: HP_ManagementProcessor
Property name Property implementation
StatusDescriptions Descriptive text per OperationalStatus.
• StatusDescriptions[0] text per OperationalStatus[0]:
○ Management Processor Status: Unknown
○ Management Processor Status: OK
○ Management Processor Status: Degraded
○ Management Processor Status: Error
• StatusDescriptions[1] text per OperationalStatus[1]:
○ Management Processor NIC Status: Unknown
○ Management Processor NIC Status: OK
○ Management Processor NIC Status: NIC is
disabled
○ Management Processor NIC Status: Not in use,
MP is utilizing host NIC
○ Management Processor NIC Status: NIC
disconnected
○ Management Processor NIC Status: NIC failed
HealthState
• 0 (Unknown), when OperationalStatus[0]=0
(Unknown), or when software interface fails
• 5 (OK), normal operation
• 10 (Degraded/Warning), when
OperationalStatus[0]=3 (Degraded)
• 20 (Major failure), when OperationalStatus[0]=6
(Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState
• 2 (Enabled) for active MP
• 3 (Disabled) for inactive/disabled MP
RequestedState 12 (Not Applicable)
EnabledDefault 2 (Enabled)
CIM_System
CreationClassName HP_ManagementProcessor
Name Product name of the management processor
Examples:
• Remote Insight Board Lights Out Edition II (RILOE-II)
• Integrated Lights Out (iLO)
• Integrated Lights Out 2 (ILO2)
CIM_ComputerSystem
Dedicated 14 (Management)
ResetCapability 4 (Enabled)
HP_ManagementProcessor