HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded
Property name Property implementation
PerceivedSeverity 5 (Major)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Advanced Memory Protection Degraded
RecommendedActions Check the Advanced Memory Protection configuration
and replace the memory board and memory modules
as necessary. Repair appropriate IML log messages
after memory is replaced.
EventID 3
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.SystemName
ProviderName HP Memory
HP_AlertIndication
Summary Advanced Memory Protection degraded
EventCategory 3 (Memory)
OSType
• For Windows 2003 32-bit: 69
• For Windows 2003 64-bit: 70
• For Windows 2008 32-bit: 76
• For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddress Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication