Table 7-26 Class: HP_SystemMemoryBoardSlot
Properties Property implementation
CIM_Container
HP_SystemMemoryBoardSlot
GroupComponent ref: HP_ComputerSystemChassis
PartComponent ref: HP_MemoryBoardSlot
7-5 Supported indications
The following indications are implemented for ProLiant server platforms where available. System
memory indications are described.
7-5-1 Memory Module Predictive Failure
Table 7-27 HP_MemoryHardwareIndication: Memory Module Predictive Failure
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
IndicationTime Time of indication
CIM_ProcessIndication
CIM_AlertIndication
Description A memory module has failed or is predicted to fail.
(MemoryModuleCaption), where MemoryModuleCaption
is the HP_MemoryModuleCaption for the failing
memory module.
AlertingManagedElement WBEM Path of HP_MemoryModule instance
representing the memory module
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 5 (Major)
ProbableCause 1 (Other)
ProbableCauseDescription Memory Module Failed or Predicted to Fail
RecommendedActions Check the memory configuration and replace memory
as necessary. Repair appropriate IML log messages
after memory is replaced.
EventID 1
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName HP_ComputerSystem.CreationClassName