Table 7-8 Class: HP_MemoryRedundancySet
Property name Property implementation
CIM_ManagedElement
Caption Memory Redundancy Set
Description Memory Redundancy Set for Advanced Memory
Protection
ElementName Memory Redundancy Set
CIM_SystemSpecificCollection
InstanceID HPQ:HP_MemoryRedundancySet:001
CIM_RedundancySet
TypeOfSet The type of redundancy currently in operation for the
Advanced Memory Protection system. This property
corresponds functionally to the property
CurrentConfiguration.
TypeOfSet[0] contains the current type of redundancy:
• 1 (Other), when the system is operating in
Advanced ECC mode
• 2 (N+1), when the system is operating in RAID
(XOR) mode
• 3 (Load Balanced), when the system is operating in
Mirrored mode
• 4 (Sparing), when the system is operating in Online
Spare mode
OtherTypeOfSet OtherTypeOfSet[0] contains the type of redundancy
when the property TypeOfSet[0] = 1 (Other). In this
case, the property will contain the value Advanced ECC
or Lockstep, otherwise the property is not populated.
LoadBalanceAlgorithm 2 (No Load Balancing)
RedundancyStatus The current memory redundancy status as follows:
• 2 (Fully Redundant)—System is operating properly
in the Advanced Memory Protection mode given in
the TargetConfiguration property.
• 3 (Degraded Redundancy)—Degraded
Redundancy can occur in either of 2 conditions:
○ System is not operating in the
TargetConfiguration mode (the
CurrentConfiguration mode does not match the
TargetConfiguration mode).
○ System is operating in the TargetConfiguration
mode but memory module(s) have correctable
errors exceeding the condition for pre-failure
warranty.
HP_MemoryRedundancySet
OperatingSpeed The current operating speed of the advanced memory
protection subsystem in MHz