HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
5-4-8 Fan Redundancy Restored
Table 5-26 HP_SensorHardwareIndication: Fan Redundancy Restored
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description Cooling redundancy for the system has been restored.
(RedundancySetCaption), where RedundancySetCaption is
HP_WinCoolingRedundancySet.Caption of the cooling
redundancy set with restored redundancy
AlertingManagedElement WBEM path of theHP_WinCoolingRedundancySet
instance representing the cooling redundancy set with
restored redundancy
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 8
ProviderName HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Cooling redundancy restored
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Cooling Redundancy has been Restored
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
• For Windows 2003 32-bit: 69
• For Windows 2003 64-bit: 70
• For Windows 2008 32-bit: 76
• For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103