HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Lost
Property name Property implementation
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-7 Fan Redundancy Gained
Table 5-25 HP_SensorHardwareIndication: Fan Redundancy Gained
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fault tolerant fan has been added to a cooling
redundancy set. (RedundancySetCaption), where
RedundancySetCaption is
HP_WinCoolingRedundancySet.Caption of the
redundancy set with an added fan
AlertingManagedElement WBEM Path of HP_WinCoolingRedundancySet
instance representing the cooling redundancy set with
an added fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 7
ProviderName HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Cooling redundancy gained
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Cooling Redundancy has been Gained
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>