HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 5-23 HP_SensorHardwareIndication: Fan Redundancy Reduced
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-6 Fan Redundancy Lost
Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Lost
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description Cooling redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinCoolingRedundancySet.Caption
for the redundancy set that lost redundancy.
AlertingManagedElement WBEM path of the HP_WinCoolingRedundancySet
instance representing the redundancy set where
redundancy was lost.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 6
ProviderName HP Cooling
RecommendedActions Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Cooling redundancy lost.