HP Insight Management WBEM Providers 2.6 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 5-18 Class: CIMElementCapacity
Property name Property implementation
Capacity References CIM_PhysicalCapacity
Element References CIM_PhysicalElement
5-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. System fan
indications are described in the following tables.
5-4-1 Fan Removed
Table 5-19 HP_SensorHardwareIndication: Fan Removed
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has been removed (FanCaption), where
FanCaption is the HP_WinFan.Captionfan number that
was removed
AlertingManagedElement WBEM path of the HP_WinCoolingCollection instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
ProviderName HP Cooling
RecommendedActions Check the fan configuration and ensure that this fan
was removed intentionally.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan removed
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Removed