Insight Management Agents 9.1 User Guide

Memory in Use—This value specifies the size of memory for this board or cartridge as seen
by the OS.
Advanced Memory Protection Condition—displays the current condition of the Advanced
Memory Protection subsystem. The following states are supported:
Other—The system does not support fault tolerant memory or the Management Agent
cannot determine the state.
OK—This system is operating normally.
Degraded— The Advanced Memory Protection sub-system has been engaged. Schedule
server down time to replace the deactivated memory.
ROM Microcode Patches
This section displays the following information about ROM Microcode Patches:
Patch ID—Displays the number of a particular microcode patch.
Date—Displays the date of a patch's manufacture.
Family—Specifies the valid family, model, and step that applies to a patch.
Model—Displays the model number of a patch.
Step—Displays the revision level of a patch.
General I/O Devices
This section displays information about the following I/O devices:
Diskette Drives—This section lists and describes the device diskette drives.
Serial and Parallel Ports—This section displays the serial ports and the parallel ports that have
been enabled for this unit, along with their corresponding I/O addresses.
The industry-standard addresses for parallel ports are as follows:
Primary Port set to 378h
Secondary Port set to 3BCh
The industry-standard addresses for serial ports are as follows:
COM1 set to 3F8h
COM2 set to 2F8h
These addresses are sometimes changed due to conflicts with another device. Communication
ports that have been disabled do not show up in this window.
136 Agent information