HP Insight Management Agents 8.40 Managing ProLiant Servers with Linux HOW TO Whitepaper

Managing ProLiant Servers with Linux HOWTO
v8.40
33
cmahealthd Host daemon to collect temperature, fan, power
supply and memory subsystem status
/opt/hp/hp-snmp-agents/server/etc/cmahealthd
{start|stop|restart|status}
cmastdeqd Host daemon to collect PCI/EISA slot information /opt/hp/hp-snmp-agents/server/etc/cmastdeqd
{start|stop|restart|status}
cmaperfd Daemon to collect performance data for CPU,
Memory, Disk and NIC
/opt/hp/hp-snmp-agents/server/etc/cmaperfd
{start|stop|restart|status}
cmasm2d Agent to collect data from iLO2/iLO/RILOE /opt/hp/hp-snmp-agents/server/etc/cmasm2d
{start|stop|restart|status}
cmarackd Agent to collect data from the ICE infrastructure /opt/hp/hp-snmp-agents/server/etc/cmarackd
{start|stop|restart|status}
Storage Agents
cmaeventd This agent is the storage interface for logging events
to the IML
/opt/hp/hp-snmp-agents/storage/etc/cmaeventd
{start|stop|restart|status}
cmaidad Agent to collect data from cciss/cpqarray drivers /opt/hp/hp-snmp-agents/storage/etc/cmaidad
{start|stop|restart|status}
cmaided Agent to collect data from IDE devices /opt/hp/hp-snmp-agents/storage/etc/cmaided
{start|stop|restart|status}
cmafcad Agent to collect data from the cpqfc driver /opt/hp/hp-snmp-agents/storage/etc/cmafcad
{start|stop|restart|status}
cmascsid Agent to collect data from SCSI storage devices /opt/hp/hp-snmp-agents/storage/etc/cmascsid
{start|stop|restart|status}
cmasasd Agent to collect data from SAS storage devices /opt/hp/hp-snmp-agents/storage/etc/cmasasd
{start|stop|restart|status}
Network Agents
cmanicd Agent to collect data from network interfaces /opt/hp/hp-snmp-agents/nic/etc/cmanicd
{start|stop|restart|status}
Note:
1. All agents support –p, –s and –t as startup parameters
2. Each agent has an associated run level script which is located in /opt/hp/hp-snmp-agents/<agent>/etc/<subagent>.
All important settings such as poll time arguments are contained in these individual scripts.
Table 19: Command line arguments for hp-snmp-agents
Command line argument Description
-p poll_time Specifies the number of seconds to wait between data collection intervals. The minimum
allowed value is 1 second and the default value is 60 seconds.
-s set_state Specifies whether SNMP set commands are allowed for this agent. A set_state of OK
(default) means that SNMP set commands are allowed. A set_state of NOT_OK means that
SNMP set commands are not allowed.