Integration for Tivoli
Appendix B: HP SNMP events 89
Tivoli types TEC class Description TEC priority
cpqSm2ServerPowerOutage
(9002)
IM_9002 This event occurs when the Remote Insight/
Integrated Lights-Out firmware has
detected server power failure.
Fatal
cpqSm2UnauthorizedLoginAttemp
ts (9003)
IM_9003 This event occurs when the Remote Insight/
Integrated Lights-Out firmware has
detected unauthorized login attempts.
Warning
cpqSm2BatteryFailed (9004)
IM_9004 This event occurs when the Remote Insight
battery has failed and must be replaced.
Critical
cpqSm2SelfTestError (9005)
IM_9005 This event occurs when the Remote Insight/
Integrated Lights-Out firmware has
detected a Remote Insight self-test error.
Critical
cpqSm2InterfaceError (9006)
IM_9006 This event occurs when the host OS has
detected an error in the Remote Insight/
Integrated Lights-Out interface, and the
firmware is not responding.
Critical
cpqSm2BatteryDisconnected
(9007)
IM_9007 This event occurs when the Remote Insight
battery cable has been disconnected.
Critical
cpqSm2KeyboardCableDisconne
cted (9008)
IM_9008 This event occurs when the Remote Insight
keyboard cable has been disconnected.
Critical
cpqSm2MouseCableDisconnecte
d (9009)
IM_9009 This event occurs when the Remote Insight
mouse cable has been disconnected.
Critical
cpqSm2ExternalPowerCableDisco
nnected (9010)
IM_9010 This event occurs when the Remote Insight
external power cable has been
disconnected.
Critical
cpqSm2LogsFull (9011)
IM_9011 This event occurs when the Remote
Insight/
Integrated Lights-Out firmware has
detected the logs are full.
Warning
cpqSm2SecurityOverrideEngaged
(9012)
IM_9012 This event occurs when the Remote Insight/
Integrated Lights-Out firmware has
detected the security override jumper has
been toggled to the engaged position.
Warning
cpqSm2SecurityOverrideDisenga
ged (9013)
IM_9013 This event occurs when the Remote Insight/
Integrated Lights-Out firmware has
detected the security override jumper has
been toggled to the disengaged position.
Warning
cpqSm2ServerFatalError (9014)
IM_9014 This event occurs when the Remote Insight/
Integrated Lights-Out firmware has
detected a fatal server error.
Fatal
cpqSm2NicLinkDown(9015)
IM_9015 This event occurs when the iLO NIC link is
down.
Fatal
cpqSm2NicLinkUp(9016)
IM_9016 This event occurs when the iLO NIC link is
up.
Harmless