Integration for Tivoli

Appendix B: HP SNMP events 85
Tivoli types TEC class Description TEC priority
cpqHe4FltTolPowerSupplyACpow
erloss
IM_6069 This event occurs when the Power Supply
AC Power Loss has occurred.
Fatal
Storage systems information (CPQSTSYS.MIB)
Tivoli types TEC class Description TEC priority
cpqSs3FanStatusChange (8008)
This event occurs when the fan status of a
storage system changes.
CpqSsBoxFanStatus:ok
IM_8008_2 Harmless
CpqSsBoxFanStatus:failed
IM_8008_3 Critical
CpqSsBoxFanStatus:noFan
IM_8008_4 Warning
CpqSsBoxFanStatus:degraded
IM_8008_5 Critical
cpqSs3TempFailed (8009)
IM_8009 This event occurs when the temperature
status has been set to failed.
Fatal
cpqSs3TempDegraded (8010)
IM_8010 This event occurs when the temperature
status has been set to degraded.
Critical
cpqSs3TempOk (8011)
IM_8011 This event occurs when the temperature
status has been set to OK.
Harmless
cpqSs3SidePanelInPlace (8012)
IM_8012 This event occurs when the storage system
side panel is in place.
Harmless
cpqSs3SidePanelRemoved (8013)
IM_8013 This event occurs when the storage system
side panel is removed.
Critical
cpqSs4PwrSupplyDegraded
(8015)
This event occurs when a storage system
power supply status has been set to
degraded.
CpqSsBoxFltTolPwrSupplyStatus:o
k
IM_8015_2 Harmless
CpqSsBoxFltTolPwrSupplyStatus:d
egraded
IM_8015_3 Critical
CpqSsBoxFltTolPwrSupplyStatus:f
ailed
IM_8015_4 Fatal
CpqSsBoxFltTolPwrSupplyStatus:n
oFltTolPower
IM_8015_5 Warning
cpqSsExPowerSupplyUpsStatusCh
ange (8018)
This event occurs when the status of an
uninterruptible power supply (UPS)
attached to a storage system power supply
changes.
CpqSsPowerSupplyUpsStatus:noU
ps
IM_8018_2 Warning
CpqSsPowerSupplyUpsStatus:ok
IM_8018_3 Harmless
CpqSsPowerSupplyUpsStatus:po
werFailed
IM_8018_4 Critical
CpqSsPowerSupplyUpsStatus:batt
eryLow
IM_8018_5 Warning
cpqSsExTempSensorStatusChang
e (8019)
This event occurs when the status of a
storage system temperature sensor
changes.
CpqSsTempSensorStatus:ok
IM_8019_2 Harmless
CpqSsTempSensorStatus:degrade
IM_8019_3 Critical