Appendix B: HP SNMP events 83
Tivoli types TEC class Description TEC priority
cpqHe3FltTolFanRedundancyLost
(6037)
IM_6037
This event occurs when the fault tolerant fans
have lost redundancy for the specified
chassis.
Critical
cpqHe3FltTolFanInserted (6038)
IM_6038 This event occurs when a fault tolerant fan
has been inserted into the specified chassis
and fan location.
Harmless
cpqHe3FltTolFanRemoved (6039)
IM_6039 This event occurs when a fault tolerant fan
has been removed from the specified
chassis and fan location.
Critical
cpqHe3TemperatureFailed (6040)
IM_6040 This event occurs when the temperature
status has been set to failed in the specified
chassis and location.
Fatal
cpqHe3TemperatureDegraded
(6041)
— This event occurs when the temperature
status has been set to degraded in the
specified chassis and location.
—
cpqHeThermalDegradedAction:co
ntinue
IM_6041_2 — Critical
cpqHeThermalDegradedAction:sh
utdown
IM_6041_3 — Critical
cpqHe3TemperatureOk (6042)
IM_6042 This event occurs when the temperature
status has been set to OK in the specified
chassis and location.
Harmless
cpqHe3PowerConverterDegraded
(6043)
IM_6043 This event occurs when the DC-DC power
converter condition has been set to
degraded for the specified chassis, slot and
socket.
Critical
cpqHe3PowerConverterFailed
(6044)
IM_6044 This event occurs when the DC-DC power
converter condition has been set to failed for
the specified chassis, slot and socket.
Fatal
cpqHe3PowerConverterRedundan
cyLost (6045)
IM_6045 This event occurs when the DC-DC power
converters have lost redundancy for the
specified chassis.
Critical
cpqHe3CacheAccelParityError
(6046)
IM_6046 This event occurs when a cache accelerator
parity error indicates a cache module must
be replaced.
Critical
cpqHeResilientMemOnlineSpareE
ngaged (6047)
IM_6047 This event occurs when the Advanced
Memory Protection subsystem has detected
a memory fault and online spare memory
has been activated.
Critical
cpqHe4FltTolPowerSupplyOk
(6048)
IM_6048 This event occurs when the fault tolerant
power supply condition has returned to the
OK state for the specified chassis and bay
location.
Harmless
cpqHe4FltTolPowerSupplyDegrad
ed (6049)
IM_6049 This event occurs when the fault tolerant
power supply condition has been set to
degraded for the specified chassis and bay
location.
Critical
cpqHe4FltTolPowerSupplyFailed
(6050)
IM_6050 This event occurs when the fault tolerant
power supply condition has been set to
failed for the specified chassis and bay
location.