Integration for Tivoli

Appendix B: HP SNMP events 82
Tivoli types TEC class Description TEC priority
cpqHe3ThermalTempOk (6019)
IM_6019 This event occurs when the server's
temperature has returned to the normal
operating range.
Harmless
cpqHe3ThermalSystemFanFailed
(6020)
This event occurs when a required system
fan is not operating normally.
cpqHeThermalDegradedAction:co
ntinue
IM_6020_2 Critical
cpqHeThermalDegradedAction:sh
utdown
IM_6020_3 Critical
cpqHe3ThermalSystemFanDegrad
ed (6021)
IM_6021 This event occurs when an optional system
fan is not operating normally.
Critical
cpqHe3ThermalSystemFanOk
(6022)
IM_6022 This event occurs when any previously
non-operational system fan has returned to
normal operation.
Harmless
cpqHe3ThermalCpuFanFailed
(6023)
IM_6023 This event occurs when a processor fan is
not operating normally.
Fatal
cpqHe3ThermalCpuFanOk
(6024)
IM_6024 This event occurs when any previously
non-operational system fan has returned to
normal operation.
Harmless
cpqHe3AsrConfirmation (6025)
IM_6025 This event occurs when the server has
previously been shutdown by the Automatic
Server Recovery (ASR) feature and has just
become operational again.
Warning
cpqHe3ThermalConfirmation
(6026)
IM_6026 This event occurs when the server has
previously been shutdown because a
thermal anomaly on the server and has just
become operational again.
Warning
cpqHe3PostError (6027)
IM_6027 This event occurs when Power On Self-Test
(POST) errors occurred during the server
restart process.
Warning
cpqHe3FltTolPwrSupplyDegraded
(6028)
IM_6028 This event occurs when the fault tolerant
power supply subsystem condition has been
set to degraded.
Critical
cpqHe3CorrMemReplaceMemMo
dule (6029)
IM_6029 This event occurs when a correctable
memory log entry indicates a memory
module must be replaced.
Warning
cpqHe3FltTolPowerRedundancyLo
st (6032)
IM_6032 This event occurs when the fault tolerant
power supplies have lost redundancy for the
specified chassis.
Critical
cpqHe3FltTolPowerSupplyInserted
(6033)
IM_6033 This event occurs when a fault tolerant
power supply has been inserted into the
specified chassis and bay location.
Harmless
cpqHe3FltTolPowerSupplyRemove
d (6034)
IM_6034 This event occurs when a fault tolerant
power supply has been removed from the
specified chassis and bay location.
Warning
cpqHe3FltTolFanDegraded
(6035)
IM_6035
This event occurs when the fault tolerant fan
condition has been set to degraded for the
specified chassis and fan.
Critical
cpqHe3FltTolFanFailed (6036)
IM_6036
This event occurs when the fault tolerant fan
condition has been set to failed for the
specified chassis and fan.
Critical