Integration for Tivoli

Appendix B: HP SNMP events 77
Tivoli types TEC class Description TEC priority
cpqDa6LogDrvStatusChange
(3034)
This event occurs when the status of a drive
array logical drive changes.
CpqDaLogDrvStatus:ok
IM_3034_2 Harmless
CpqDaLogDrvStatus:failed
IM_3034_3 Fatal
CpqDaLogDrvStatus:recovering
IM_3034_4 Warning
CpqDaLogDrvStatus:unconfigured
IM_3034_5 Warning
CpqDaLogDrvStatus:readyForReb
uild
IM_3034_6 Warning
CpqDaLogDrvStatus:rebuilding
IM_3034_7 Warning
CpqDaLogDrvStatus:wrongDrive
IM_3034_8 Warning
CpqDaLogDrvStatus:badConnect
IM_3034_9 Critical
CpqDaLogDrvStatus:overheating
IM_3034_1
0
Critical
CpqDaLogDrvStatus:shutdown
IM_3034_1
1
Critical
CpqDaLogDrvStatus:expanding
IM_3034_1
2
Warning
CpqDaLogDrvStatus:notAvailable
IM_3034_1
3
Warning
CpqDaLogDrvStatus:queuedForEx
p
IM_3034_1
4
Warning
CpqDaLogDrvStatus:multipathAcc
essDegraded
IM_3034_1
5
Warning
cpqDa6SpareStatusChange
(3035)
This event occurs when the status of a drive
array spare drive changes.
CpqDaSpareStatus:invalid
IM_3035_2 Warning
CpqDaSpareStatus:failed
IM_3035_3 Fatal
CpqDaSpareStatus:inactive
IM_3035_4 Harmless
CpqDaSpareStatus:building
IM_3035_5 Warning
CpqDaSpareStatus:active
IM_3035_6 Warning
cpqDa6PhyDrvStatusChange
(3036)
This event occurs when the status of a drive
array physical drive changes.
CpqDaPhyDrvStatus:ok
IM_3036_2 Harmless
CpqDaPhyDrvStatus:failed
IM_3036_3 Fatal
CpqDaPhyDrvStatus:predictiveFail
ure
IM_3036_4 Critical
cpqDa6PhyDrvThreshPassedTrap
(3037)
IM_3037
This event occurs when a factory threshold
associated with one of the physical drive
objects on a drive array has been
exceeded.
Critical
cpqDa6AccelStatusChange
(3038)
This event occurs when the status of an
array accelerator cache board changes.
CpqDa5AccelStatus:invalid
IM_3038_2 Warning
CpqDa5AccelStatus:
IM_3038_3 Harmless
CpqDa5AccelStatus:tmpDisabled
IM_3038_4 Critical
CpqDa5AccelStatus:permDisable
d
IM_3038_5 Critical
cpqDa6AccelBadDataTrap
IM_3039 This event occurs when an array Critical